Patient state index vs bispectral index as measures of the electroencephalographic effects of propofol
Authors:
Open Access
- 29 June 2010
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 105 (2) , 172-178
Abstract
The patient state index (PSI) and the bispectral index (BIS) quantify anaesthetic depth based on the EEG using different algorithms. We compared both indices with regard to the prediction of the depth of propofol anaesthesia. In 17 patients, propofol was infused until burst suppression occurred and stopped thereafter until BIS recovered to values above 60. This was repeated; afterwards, patients were intubated, for subsequent surgery. Without surgical stimulus, PSI and BIS were measured simultaneously and compared with the estimated effect-site concentrations of propofol. These were derived from simultaneous pharmacokinetic and -dynamic modelling in an individual two-stage and a population-based NONMEM approach. A close sigmoid relationship was observed between the propofol effect-site concentration and both PSI [coefficient of determination ρ2=0.91 (sd 0.05)] and BIS [ρ2=0.92 (0.03)], which was significantly steeper for PSI [γ=2.2 (0.6)] than for BIS [γ=1.8 (0.4)], and reached significantly lower values for PSI [Emax=0.3 (1.1)] than for BIS [Emax=5.3 (6.7)] at maximal propofol concentrations. A significantly smaller ke0 was obtained for PSI [0.09 (0.03) min−1] compared with BIS [0.10 (0.02) min−1]. PSI and BIS correlated significantly with each other (ρ2=0.866) and predicted propofol effect-site concentration with a comparable probability [PK=0.87 (0.05) and 0.86 (0.05), respectively]. NONMEM revealed E0=89.3 and 92.3, Emax=1.9 and 8.6, Ce50=1.38 and 1.92 µg ml−1, γ=1.6 and 1.48, and ke0=0.103 and 0.131 min−1 as typical values for PSI and BIS, respectively. The PSI and the BIS monitors performed equally well in predicting depth of propofol anaesthesia. However, PSI was lower than BIS by ∼10–15 points at high propofol concentrations.Keywords
This publication has 26 references indexed in Scilit:
- Pharmacokinetic models for propofol—defining and illuminating the devil in the detailBritish Journal of Anaesthesia, 2009
- Comparison between Bispectral Index and Patient State Index as Measures of the Electroencephalographic Effects of SevofluraneAnesthesiology, 2008
- Depth of anaesthesia monitoring: what’s available, what’s validated and what’s next?British Journal of Anaesthesia, 2006
- Spectral Entropy and Bispectral Index as Measures of the Electroencephalographic Effects of SevofluraneAnesthesiology, 2004
- Patient State IndexAnesthesiology, 2002
- A Primer for EEG Signal Processing in AnesthesiaAnesthesiology, 1998
- The Influence of Method of Administration and Covariates on the Pharmacokinetics of Propofol in Adult VolunteersAnesthesiology, 1998
- Measuring the Performance of Anesthetic Depth IndicatorsAnesthesiology, 1996
- PHARMACOKINETIC MODEL DRIVEN INFUSION OF PROPOFOL IN CHILDRENBritish Journal of Anaesthesia, 1991
- Simultaneous modeling of pharmacokinetics and pharmacodynamics: Application to d‐tubocurarineClinical Pharmacology & Therapeutics, 1979