Vital signs and cognitive function are not affected by 23‐sodium and 17‐oxygen magnetic resonance imaging of the human brain at 9.4 T
Authors:
- Ian C. AtkinsonIAIan C. Atkinson
- Rachel SonstegaardRSRachel Sonstegaard
- Neil H. PliskinNPNeil H. Pliskin
- Keith R. ThulbornKTKeith R. Thulborn
- 23 June 2010
- journal article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (1) , 82-87
Abstract
Purpose: To evaluate the effect of 23‐sodium (23Na) and 17‐oxygen (17O) magnetic resonance imaging (MRI) at 9.4 (T) on vital signs and cognitive function of the human brain.Materials and Methods: Vital sign and cognitive function measurements from healthy volunteers (N = 14) positioned outside and at isocenter of a 9.4 T scanner before and after 23Na and 17O MRI were compared for changes due to exposure to the static magnetic field and to the gradient switching and radiofrequency radiation during MRI.Results: Exposure to the 9.4 T static magnetic field and 23Na and 17O MRI at 105.92 MHz and 54.25 MHz, respectively, did not have a statistically significant (P > 0.05) effect on the vital signs or cognitive function of healthy normal adults.Conclusion: 23Na and 17O MRI of the human brain at 9.4 T does not have any readily demonstrated health risks reflected in vital signs or change in cognitive performance. J. Magn. Reson. Imaging 2010;32:82–87.Keywords
This publication has 15 references indexed in Scilit:
- High‐Resolution Phased‐Array MRI of the Human Brain at 7 Tesla: Initial Experience in Multiple Sclerosis PatientsJournal of Neuroimaging, 2010
- Quantitative Sodium MR Imaging and Sodium Bioscales for the Management of Brain TumorsNeuroimaging Clinics Of North America, 2009
- High‐resolution 7T MRI of the human hippocampus in vivoJournal of Magnetic Resonance Imaging, 2008
- Safety of human MRI at static fields above the FDA 8T guideline: Sodium imaging at 9.4T does not affect vital signs or cognitive abilityJournal of Magnetic Resonance Imaging, 2007
- 9.4T human MRI: Preliminary resultsMagnetic Resonance in Medicine, 2006
- Randomized comparison of cognitive function in humans at 0 and 8 TeslaJournal of Magnetic Resonance Imaging, 2003
- Effect of static magnetic field exposure of up to 8 Tesla on sequential human vital sign measurementsJournal of Magnetic Resonance Imaging, 2003
- Zoomed Functional Imaging in the Human Brain at 7 Tesla with Simultaneous High Spatial and High Temporal ResolutionNeuroImage, 2002
- Biological effects and health implications in magnetic resonance imagingConcepts in Magnetic Resonance, 2000
- Cognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imagingMagnetic Resonance Imaging, 1999