Evaluation of the predictors and frequency of silent hypoxemia in COVID‐19 patients and the gap between pulse oximeter and arterial blood gas levels: A cross‐sectional study
Open Access
- 17 June 2024
- journal article
- research article
- Published by Wiley in Health Care Science
- Vol. 3 (3) , 172-180
Abstract
Background: Silent hypoxemia is when patients do not experience breathing difficulty in the presence of alarmingly low O2 saturation. It could cause rapid deterioration and higher mortality rates among patients, so prompt detection and identifying predictive factors could result in significantly better outcomes. This study aims to document the evidence of silent hypoxemia in patients with COVID‐19 and its clinical features.Methods: A total of 78 hospitalized, nonintubated patients with confirmed COVID‐19 infection were included in this study. Their O2 saturation was measured with a pulse oximeter (PO), and arterial blood gas (ABG) was taken. Demographic and clinical features were recorded. The Borg scale was used to evaluate dyspnea status, and patients with a score of less than two accompanied by O2 saturation of less than 94% were labeled as silent hypoxic. Univariate analysis was utilized to evaluate the correlation between variables and their odds ratio (OR) and 95% confidence interval (CI).Results: Silent hypoxemia was observed in 20 (25.6%) of the participants. The average difference between the PO and ABG methods was 4.36 ± 3.43. Based on regression analysis, dyspnea and respiratory rate demonstrated a statistically significant correlation with the O2 saturation difference between PO and ABG (OR: 2.05; p = 0.026; 95% CI: 0.248–3.847 and OR: 0.144; p = 0.048, 95% CI: 0.001–0.286). Furthermore, the Borg scale (OR: 0.29; p = 0.009; 95% CI: 0.116–0.740) had a significant reverse correlation with silent hypoxia.Conclusions: Silent hypoxemia can be a possible complication that affects some COVID‐19 patients. Further care should be bestowed upon the younger population and those with underlying neurological or mental illnesses. Furthermore, the respiratory rate, pulse oximeter, and arterial blood gas O2 levels should be considered alongside each other.Keywords
This publication has 31 references indexed in Scilit:
- Epidemiological and clinical characteristics of 99 cases of 2019 novel coronavirus pneumonia in Wuhan, China: a descriptive studyThe Lancet, 2020
- Clinical features of patients infected with 2019 novel coronavirus in Wuhan, ChinaThe Lancet, 2020
- Current and emerging trends in point-of-care urinalysis testsExpert Review of Molecular Diagnostics, 2019
- Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probesBMC Nursing, 2018
- Pulse Oximetry Overestimates Oxygen Saturation in COPDRespiratory Care, 2015
- A Novel Coronavirus Associated with Severe Acute Respiratory SyndromeNew England Journal of Medicine, 2003
- Usefulness of the modified 0-10 Borg scale in assessing the degree of dyspnea in patients with COPD and asthmaJournal of Emergency Nursing, 2000
- Reproducibility of Borg Scale Measurements of Dyspnea During Exercise in Patients With COPDChest, 1995
- Pulse OximetryChest, 1990
- Inapparent Hypoxemia in Casualties with Wounded LimbsAnnals of Surgery, 1968