A Fast Neural Network for Isotopic Charge State Assignment
Preprint
- 17 April 2025
- preprint
- Published by American Chemical Society (ACS) in ChemRxiv
Abstract
Electrospray ionization (ESI) mass spectrometry is an essential technique for chemical analysis in a range of fields. In ESI, analytes can produce multiple charge states, which must be correctly assigned for identification. Existing approaches to charge state assignment can suffer from limited accuracy and/or poor speed. Here, we developed a fast neural network to perform isotopic envelope charge assignment. The performance of our algorithm, IsoDec, was demonstrated on top-down proteomics spectra collected on diverse instruments. On these highly complex individual spectra, we found that IsoDec correctly assigns more features compared to existing software tools while simultaneously providing improved speed and accuracy. Importantly, this performance enhancement stems directly from the neural network charge assignment approach, not simply improved scoring and filtering of isotopic envelopes. Finally, when applied to large top-down proteomics data sets, we discovered that database searching of IsoDec deconvolution output produces proteoform-spectrum matches with a better combination of coverage and accuracy. Overall, IsoDec provides a compelling demonstration of the potential of lightweight neural networks in mass spectrometry data analysis for diverse applications.Keywords
All Related Versions
Funding Information
- National Institute of General Medical Sciences (R01GM147653)
- National Institute of General Medical Sciences (T32GM135066)
This publication has 56 references indexed in Scilit:
- Spectral averaging with outlier rejection algorithms to increase identifications in top‐down proteomicsProteomics, 2024
- PyTorch2021
- Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence AnalysisJournal of the American Society for Mass Spectrometry, 2017
- Improved Peak Detection and Deconvolution of Native Electrospray Mass Spectra from Large Protein ComplexesJournal of the American Society for Mass Spectrometry, 2015
- ProSight Lite: Graphical software to analyze top‐down mass spectrometry dataProteomics, 2014
- Isotopic Distributions2013
- Resolving stoichiometries and oligomeric states of glutamate synthase protein complexes with curve fitting and simulation of electrospray mass spectraRapid Communications in Mass Spectrometry, 2006
- Disentangling electrospray spectra with maximum entropyRapid Communications in Mass Spectrometry, 1992
- The Application of Maxent to Electrospray Mass Spectrometry1992
- Maximum entropy deconvolution in electrospray mass spectrometryRapid Communications in Mass Spectrometry, 1991