Abstract
Purpose: Standardization and international guidelines for stent size selection are lacking. In this study, we introduce and validate an artificial intelligence (AI)- and image processing-supported, modular software algorithm trained on a multicentric vascular segmentation dataset that identifies stenoses, performs segmentations of stenotic vessel segments and suggests the optimal stent size for implantation. Material and methods: This retrospective multicenter study included 149 patients who underwent stent implantation for symptomatic stenoses of the common and external iliac arteries between August 2017 and July 2024. Peri-interventional angiography datasets were evaluated by four board-certified interventional radiologists. For AI-training, all relevant stenoses were annotated and segmented to reflect intended stent sizing. The segmentation criteria were consensus-defined, and all readers completed a prior training session to ensure consistency. The modular algorithm comprises components for stenosis detection, segmentation and stent parameter prediction. Following pre-training on a publicly available coronary artery dataset, the model was fine-tuned on the study-specific iliac artery dataset using leave-one-out cross-validation. Results: OSCAR detected stenoses in 84.6% of cases. The model achieved a high recall (0.89 ± 0.21), meaning that most expert-annotated stenoses were correctly identified, while a moderate precision (0.65 ± 0.28) indicated some false-positive detections. Segmentation accuracy was good (DSC 0.77 ± 0.11). Stent diameter and length predictions demonstrated mean absolute percentage errors of 0.13 ± 0.18 and 0.33 ± 0.31, respectively, comparable to expert variability. Conclusions: This proof-of-concept study demonstrates the potential of AI-assisted stent selection in vascular interventions. Furthermore, the option of a closed-loop framework promotes sustainability, reproducibility and cost-effectiveness in stent implantation procedures.Keywords
Funding Information
- Schleswig-Holstein
- Universitätsklinikum Schleswig-Holstein - Campus Lübeck
This publication has 26 references indexed in Scilit:
- High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography: Lumen Size and Plaque MorphologyJournal of the Society for Cardiovascular Angiography & Interventions, 2025
- Artificial Intelligence in Coronary Artery Interventions: Preprocedural Planning and Procedural AssistanceJournal of the Society for Cardiovascular Angiography & Interventions, 2025
- Impact of Artificial Intelligence-Enhanced Optical Coherence Tomography Software on Percutaneous Coronary Intervention DecisionsJournal of the Society for Cardiovascular Angiography & Interventions, 2025
- Artificial intelligence in interventional radiology: Current concepts and future trendsDiagnostic and Interventional Imaging, 2024
- CARS 2024—Computer Assisted Radiology and Surgery Proceedings of the 38th International Congress and Exhibition Barcelona, Spain, June 18–21, 2024International Journal of Computer Assisted Radiology and Surgery, 2024
- Global Burden of Cardiovascular Diseases and Risks, 1990-2022JACC, 2023
- Clinical impact of undersized- versus oversized-stenting approaches in ST-elevation myocardial infarctionCardiovascular Revascularization Medicine, 2016
- Intravascular Ultrasound Assessment of Acute Expansion of the Balloon-expandable Stent in Heavy Calcified Iliac Artery Lesions or in Lesions Resistant to Dilation by a Self-expanding StentAnnals of Vascular Surgery, 2014
- Optimal Stent-Sizing With Intravascular Ultrasound Contributes to Complete Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by AngioscopyJACC: Cardiovascular Interventions, 2009
- Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantationJACC, 2005