Effects of spectrometer band pass, sampling, and signal‐to‐noise ratio on spectral identification using the Tetracorder algorithm
Open Access
- 10 September 2003
- journal article
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research
- Vol. 108 (E9)
Abstract
Estimates of spectrometer band pass, sampling interval, and signal‐to‐noise ratio required for identification of pure minerals and plants were derived using reflectance spectra convolved to AVIRIS, HYDICE, MIVIS, VIMS, and other imaging spectrometers. For each spectral simulation, various levels of random noise were added to the reflectance spectra after convolution, and then each was analyzed with the Tetracorder spectral identification algorithm [Clark et al., 2003]. The outcome of each identification attempt was tabulated to provide an estimate of the signal‐to‐noise ratio at which a given percentage of the noisy spectra were identified correctly. Results show that spectral identification is most sensitive to the signal‐to‐noise ratio at narrow sampling interval values but is more sensitive to the sampling interval itself at broad sampling interval values because of spectral aliasing, a condition when absorption features of different materials can resemble one another. The band pass is less critical to spectral identification than the sampling interval or signal‐to‐noise ratio because broadening the band pass does not induce spectral aliasing. These conclusions are empirically corroborated by analysis of mineral maps of AVIRIS data collected at Cuprite, Nevada, between 1990 and 1995, a period during which the sensor signal‐to‐noise ratio increased up to sixfold. There are values of spectrometer sampling and band pass beyond which spectral identification of materials will require an abrupt increase in sensor signal‐to‐noise ratio due to the effects of spectral aliasing. Factors that control this threshold are the uniqueness of a material's diagnostic absorptions in terms of shape and wavelength isolation, and the spectral diversity of the materials found in nature and in the spectral library used for comparison. Array spectrometers provide the best data for identification when they critically sample spectra. The sampling interval should not be broadened to increase the signal‐to‐noise ratio in a photon‐noise‐limited system when high levels of accuracy are desired. It is possible, using this simulation method, to select optimum combinations of band‐pass, sampling interval, and signal‐to‐noise ratio values for a particular application that maximize identification accuracy and minimize the volume of imaging data.Keywords
This publication has 31 references indexed in Scilit:
- Imaging spectroscopy: Earth and planetary remote sensing with the USGS Tetracorder and expert systemsJournal of Geophysical Research, 2003
- Mapping vegetation in Yellowstone National Park using spectral feature analysis of AVIRIS dataRemote Sensing of Environment, 2003
- Using Imaging Spectroscopy To Map Acidic Mine WasteEnvironmental Science & Technology, 1999
- Derivation of scaled surface reflectances from AVIRIS dataRemote Sensing of Environment, 1993
- The airborne visible/infrared imaging spectrometer (AVIRIS)Remote Sensing of Environment, 1993
- Mapping playa evaporite minerals with AVIRIS data: A first report from death valley, CaliforniaRemote Sensing of Environment, 1993
- High spectral resolution reflectance spectroscopy of mineralsJournal of Geophysical Research, 1990
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978
- Spectral signatures of particulate minerals in the visible and near infraredGeophysics, 1977
- Infra-red hydroxyl frequencies of muscovite, phlogopite and biotite micas in relation to their structuresTransactions of the Faraday Society, 1964