Titanium Mesh and Bone Dust Calvarial Patch during Cranioplasty
Authors:
- 1 July 1997
- journal article
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 34 (4) , 354-356
Abstract
A technique of filling calvarial detects using bone dust reinforced with titanium Micro Mesh (Leibinger®) was investigated using plain x-ray films and computed tomography (CT) in seven consecutive patients (age range, 7–21 years). The aim of our study was to assess whether, in the presence of the titanium, bone dust harvested with a power burr promotes persistent ossification that is comparable with adjacent bone. The mesh was localized by standard skull plain x-ray films, and orthogonal CT scans were obtained at between 9 and 18 months post-operatively. An ultrahigh-resolution algorithm was used to detect neoossification on either side of the Micro Mesh (1-mm collimation, 330-mA and 120 KV(p) at the center of 400 HU, and window width of 2000 Hu). The mesh induced minimal streak artifact. Virtually no new bone formation was seen. It appears that bone dust was completely reabsorbed in this patient group even in the presence of semi-rigid fixation.Keywords
This publication has 13 references indexed in Scilit:
- Mandibular reconstruction with cancellous bone, hydroxylapatite and titanium meshJournal of Cranio-Maxillofacial Surgery, 1994
- Scientific FoundationJournal of Craniofacial Surgery, 1993
- Calvarial Reconstruction in Baboons with Porous HydroxyapatiteJournal of Craniofacial Surgery, 1992
- DEMINERALIZED BONE MATRIX/ POLYDIOXANONE COMPOSITE AS A SUBSTITUTE FOR BONE GRAFTJournal of Craniofacial Surgery, 1992
- Comparison of Inorganic Bovine Bone Mineral Particles with Porous Hydroxyapatite Granules and Cranial Bone Dust in the Reconstruction of Full-thickness Skull DefectJournal of Craniofacial Surgery, 1992
- Titanium in reconstructive surgery of the skull and faceBritish Journal of Plastic Surgery, 1990
- The Skull As a Bone Graft Donor SiteAnnals of Plastic Surgery, 1983
- REPAIR OF MAJOR CRANIO-ORBITAL DEFECTS WITH AN ELASTOMER-COATED MESH AND AUTOGENOUS BONE PASTEPlastic and Reconstructive Surgery, 1978
- BONE DUST CRANIOPLASTYPlastic and Reconstructive Surgery, 1977
- Skull reconstruction with bone dustBritish Journal of Plastic Surgery, 1970