Laboratory Evaluation of Femtosecond Laser Lamellar Cuts in Gamma-Irradiated Corneas
Authors:
- Liang LiuLLLiang Liu
- Maolong TangMTMaolong Tang
- Yan LiYLYan Li
- Winston ChamberlainWCWinston Chamberlain
- David HuangDHDavid Huang
- 1 November 2015
- journal article
- basic investigation
- Published by Wolters Kluwer Health in Cornea
- Vol. 34 (11) , 1499-1503
Abstract
Purpose: To evaluate the stromal interface quality after femtosecond laser full lamellar cuts in gamma-irradiated corneas (VisionGraft sterile cornea) and to determine the limits of the cut depth using the VisionGraft as donor corneas for laser-assisted lamellar anterior keratoplasty. Methods: Fourteen VisionGraft corneas underwent full lamellar cuts using the femtosecond laser. The percent cut depth was 17% to 21% (100 μm, n = 2), 31% to 35% (n = 3), 38% to 40% (n = 3), 45% to 48% (n = 3), and 50% (n = 3) of the total stromal thickness (not including the epithelium). The cap and stromal bed surfaces were imaged with a scanning electron microscope. The quality of cut surfaces was graded by 2 masked observers based on two indices: ridge and roughness. Ridge grading indicated macroscopic irregularity. Roughness grading indicated microscopic irregularity. The grading was done on a subjective integer scale of 1 to 5 (1 = best and 5 = worst), which was used in a previous study of cut quality in fresh corneas. Results: The ridge grading ranged from 1.5 for the shallowest cut to 2.2 for the deepest cut and weakly (r = 0.279) but significantly (P = 0.037) correlated with the percent cut depth. The roughness grading ranged from 2.63 to 2.56 and showed no trend with the percent cut depth (r = 0.006, P = 0.968). Conclusions: Compared with previously published results of fresh corneas, in which ridge grading exceeded 3 for cuts deeper than 31%, cut quality was better for the VisionGraft. Even at depths up to 48% of the total stromal thickness, ridge grading was not worse than shallow cuts. Thus, gamma-irradiated corneas could provide a smoother interface than do fresh eye bank corneas for laser-assisted lamellar anterior keratoplasty.Keywords
This publication has 20 references indexed in Scilit:
- Quality of corneal lamellar cuts quantified using atomic force microscopyJournal of Cataract & Refractive Surgery, 2013
- Femtosecond Laser and Big-Bubble Deep Anterior Lamellar Keratoplasty: A New ChanceJournal of Ophthalmology, 2012
- The Intraoperative Impression and Postoperative Outcomes of Gamma-Irradiated Corneas in Corneal and Glaucoma Patch SurgeryCornea, 2011
- Deep Anterior Lamellar Keratoplasty as an Alternative to Penetrating KeratoplastyOphthalmology, 2011
- Lamellar Keratoplasty Using Gamma-Irradiated Corneal LenticulesAmerican Journal of Ophthalmology, 2011
- Multimodal Nonlinear Imaging of the Human CorneaInvestigative Ophthalmology & Visual Science, 2010
- Deep anterior lamellar keratoplasty performed with the femtosecond laser zigzag incision for the treatment of stromal corneal pathology and ectatic diseaseJournal of Cataract & Refractive Surgery, 2009
- Deep anterior lamellar keratoplasty with femtosecond-laser zigzag incisionsJournal of Cataract & Refractive Surgery, 2009
- Femtosecond laser versus manual dissection for top hat penetrating keratoplastyBritish Journal of Ophthalmology, 2008
- Femtosecond laser–assisted posterior lamellar keratoplastyInitial studies of surgical technique in eye bank eyesOphthalmology, 2005