Large-Eddy Simulation of Two-Phase Flow in Air-Sparged Hydrocyclone

Authors:

Abstract
Two-phase flow of air and water in a 2-inch Air-Sparged Hydrocyclone (ASH) is computed using Large-Eddy Simulation of two-fluid (Euler-Euler) model. The computational mesh is a block-structured O-type grid that has 10.5 Million hexagonal elements. A uniform air bubble diameter of 0.5 mm has been specified. The LES model has been validated by comparison with experimental data for a conventional classifying hydrocyclone [1]. The flow field in ASH has been investigated for inlet flow rate of water of 30.6 L/min at different values of underflow exit pressure. The present LES simulations show that the distribution of air volume fraction, water axial velocity, tangential velocity and swirling layer thickness depend on the value of static pressure imposed at the underflow section. The loci of zero-axial velocity surfaces have been determined from the profiles of axial velocity. The water split ratio through the overflow opening vary with underflow exit pressure as 6%, 8%, 16% and 26% for 3, 4, 5, and 6 kPa, respectively. These results indicate that regulating the pressure at the underflow exit can be used to optimize the performance of ASH.