External Validation of Fully-Automated Infrarenal Maximum Aortic Aneurysm Diameter Measurements in Computed Tomography Angiography Scans Using Artificial Intelligence (PRAEVAorta 2)
Authors:
- Johannes HatzlJHJohannes Hatzl
- Jonathan FieringJFJonathan Fiering
- Kak K YeungKYKak K Yeung
- Bram FiooleBFBram Fioole
- Eric VerhoevenEVEric Verhoeven
- Athanasios KatsargyrisAKAthanasios Katsargyris
Open Access
- 13 November 2024
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
Abstract
Purpose: This study investigates the accuracy of fully-automated maximum aortic diameter measurements in abdominal aortic aneurysm (AAA) patients using artificial intelligence software (PRAEVAorta 2, Nurea, Bordeaux, France). Materials and Methods: This is a multicenter, retrospective validation study using prospectively collected data from the Zenith alpha for aneurysm Repair Registry (ZEPHYR). Automated measurements of PRAEVAorta 2 are compared with measurements of an internationally recognized core laboratory (Syntactx, New York, New York State). The reviewers at the core laboratory were measurement technologists trained to and utilizing established measurement standards, overseen by vascular surgeons and radiologists. The data set comprised 871 computed tomography angiography scans from the ZEPHYR registry with 347 patients who underwent endovascular aneurysm repair (EVAR) with the Zenith Alpha Endovascular Abdominal Graft (Cook Medical, Bloomington, Indiana) in Germany, Belgium, and The Netherlands between 2016 and 2019. Results: The analysis demonstrated excellent correlation of the measurements (r=0.97) with an intraclass correlation (ICC) of 0.972 (95% confidence interval [CI]=0.968-0.976) across all scans. For preoperative computed tomography (CT) scans, ICC was 0.953 (95% CI=0.941-0.963), and for postoperative scans, ICC was 0.979 (95% CI=0.975-0,983), respectively. In total, 95.4% of measurements were within the clinically acceptable range of 5 mm in absolute difference. In total, 10% of scans demonstrated obvious segmentation errors, mainly due to failure in detecting vessel segments (renal arteries, aortic bifurcation) or due to mis-detecting the outer border of the AAA (duodenum, inferior vena cava, aortic branches) and were excluded from the analysis. Conclusion: In this study, the maximum AAA diameter could be accurately measured fully-automatically by PRAEVAorta 2 (Nurea) in most cases demonstrating that artificial intelligence (AI) software could serve as an important adjunct for research and clinical practice. However, critical review of the generated reports by an experienced observer and cautious use is warranted to identify flawed segmentations. Clinical Impact: This multicenter, retrospective validation study assessed the accuracy of fully-automated maximum infrarenal aortic aneurysm diameter measurements. It was demonstrated, that 95.4% of measurements were within the clinically acceptable range of 5 mm in absolute difference, positioning the software as a potential adjunct for clinical practice and research. It is also highlighted however, that critical review of the measurements is obligatory, due to a 10% segmentation error rate.Keywords
This publication has 18 references indexed in Scilit:
- Multicentric clinical evaluation of a computed tomography-based fully automated deep neural network for aortic maximum diameter and volumetric measurementsJournal of Vascular Surgery, 2024
- Fully automatic volume segmentation using deep learning approaches to assess aneurysmal sac evolution after infrarenal endovascular aortic repairJournal of Vascular Surgery, 2022
- Thirty-day Results from the ZEPHYR Registry: Outcomes of EVAR Using the Zenith Alpha™ Abdominal Endovascular Graft for the Treatment of AAA in 347 PatientsAnnals of Vascular Surgery, 2022
- Pre-surgical and Post-surgical Aortic Aneurysm Maximum Diameter Measurement: Full Automation by Artificial IntelligenceEuropean Journal of Vascular and Endovascular Surgery, 2021
- Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-upEuropean Journal of Radiology, 2021
- Artificial intelligence in vascular surgery: The next gold rush or busted flush?Journal of Vascular Surgery, 2020
- The Need for Standardized Methods for Measuring the AortaJACC: Cardiovascular Imaging, 2016
- Standardization and Optimization of CT Protocols to Achieve Low DoseJournal of the American College of Radiology, 2014
- The Society for Vascular Surgery Vascular Quality InitiativeJournal of Vascular Surgery, 2012
- Variability of maximal aortic aneurysm diameter measurements on CT scan: significance and methods to minimizeJournal of Vascular Surgery, 2004