Biomechanical Analysis of the Brachioradialis as a Donor in Tendon Transfer
Authors:
- D AlbrechtDAD Albrecht
- R L LieberRLR L Lieber
- 1 February 2001
- journal article
- review article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 383 (383) , 152-161
Abstract
Anatomic and biomechanical properties of the passive brachioradialis muscle were investigated to understand the limited excursion of this muscle seen during tendon transfer surgery. First, architectural measurements were performed on three fiber bundles obtained from four regions of the brachioradialis (10 specimens) chosen to represent the range of muscle fiber lengths across the brachioradialis. Next, in separate specimens (eight specimens), passive excursion was measured by securing the distal tendon stump to a servomotor. A constant load of 4.9 N was applied to the tendon, while the distal tendon was released from the surrounding tissue in 3-cm increments. Within the four regions studied, muscle fiber length varied significantly from 104.2 +/- 6.2 mm to 179.8 +/- 6.1 mm. As the brachioradialis was released, an average of 3 mm of mobility was obtained for each interval whereas for the succeeding three intervals, an average of 5.3 mm of mobility was obtained. This resulted in 22.2 +/- 2.3 mm of mobility when each specimen was fully released. These data show that there is no intrinsic muscle fiber length limitation to excursion, but that excursion is limited by other intermuscular connections to adjacent connective tissue and other muscles.Keywords
This publication has 11 references indexed in Scilit:
- Sarcomere Length changes after flexor carpi ulnaris to extensor digitorum communis tendon transferThe Journal of Hand Surgery, 1996
- Willis and steno on muscles: Rediscovery of a 17th‐century biological theory*Journal of the History of the Neurosciences, 1996
- In vivo measurement of human wrist extensor muscle sarcomere length changesJournal of Neurophysiology, 1994
- Architecture of selected muscles of the arm and forearm: Anatomy and implications for tendon transferThe Journal of Hand Surgery, 1992
- Quantitative method for comparison of skeletal muscle architectural propertiesJournal of Biomechanics, 1992
- Architecture of selected wrist flexor and extensor musclesThe Journal of Hand Surgery, 1990
- Tendon excursion and moment arm of index finger musclesJournal of Biomechanics, 1983
- Architecture of the hind limb muscles of cats: Functional significanceJournal of Morphology, 1982
- Relative tension and potential excursion of muscles in the forearm and handThe Journal of Hand Surgery, 1981
- Tendon Transfers for Median and Ulnar Nerve ParalysisOrthopedic Clinics of North America, 1970