Abstract
The performances of core–shell 2.7 μm and fully porous sub‐2 μm particles packed in narrow diameter columns were compared under the same chromatographic conditions. The stationary phases were compared for fast separation and determination of five new antiviral drugs; daclatasvir, sofosbuvir, velpatasvir, simeprevir, and ledipasvir. The gradient elution was done using ethanol as green organic modifier, which is more environmentally friendly. Although both columns provided very good resolution of the five drugs, core–shell particles had proven to be of better efficiency. Under gradient elution conditions, core–shell particles exhibited faster elution, better peak shape, and enhanced resolution adding to lower system backpressure. The column backpressure on sub‐2 μm particles was more than twice that on core–shell particles. This gives a chance to use conventional high‐performance liquid chromatography conditions without needing special instrumentation as that required for ultra‐high performance liquid chromatography. The method was validated for determination of the five drugs by gradient elution using mobile phase composed of organic modifier ethanol and aqueous part containing 0.75 g sodium octane sufonate and 3.0 g sodium dihydrogen phosphate per liter at pH of 6.15. Detection was done using UV‐detector set at 210 nm. The linearity, accuracy, and precision were found very good within the concentration range of 2–200 μg/mL.Keywords
This publication has 32 references indexed in Scilit:
- Comparison of a new high‐resolution monolithic column with core‐shell and fully porous columns for the analysis of retinol and α‐tocopherol in human serum and breast milk by ultra‐high‐performance liquid chromatography†Journal of Separation Science, 2013
- Performance characteristics of new superficially porous particlesJournal of Chromatography A, 2012
- A sensitive and accurate liquid chromatography–tandem mass spectrometry method for quantitative determination of the novel hepatitis C NS5A inhibitor BMS-790052 (daclastasvir) in human plasma and urineJournal of Chromatography A, 2012
- A rugged and accurate liquid chromatography–tandem mass spectrometry method for quantitative determination of BMS-790052 in plasmaJournal of Chromatography B, 2011
- Characterization of new types of stationary phases for fast liquid chromatographic applicationsJournal of Pharmaceutical and Biomedical Analysis, 2009
- Critical comparison of performances of superficially porous particles and sub-2μm particles under optimized ultra-high pressure conditionsJournal of Chromatography A, 2009
- Advantages of application of UPLC in pharmaceutical analysisTalanta, 2006
- Advancing LC Performance with Smaller Particles and Higher PressureAnalytical Chemistry, 2005
- Ultrahigh-Pressure Reversed-Phase Liquid Chromatography in Packed Capillary ColumnsAnalytical Chemistry, 1997
- Superficially porous silica microspheres for the fast high-performance liquid chromatography of macromoleculesAnalytical Chemistry, 1992