Development and characterization of a high sensitivity segmented Fast Neutron Spectrometer (FaNS-2)
Authors:
- 1 January 2016
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (01) , P01006
Abstract
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and 3He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a 3He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron fluxes. A main goal of its design is to study comparatively low neutron fluxes, such as cosmogenic neutrons at the Earth's surface, in an underground environment, or from low-activity neutron sources. In this paper, we present details of its design and construction as well as its characterization with a calibrated 252Cf source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected monoenergetic neutron spectra are unfolded using a Singular Value Decomposition method, demonstrating a 5% energy resolution at 14 MeV. Finally, we discuss plans for measuring the surface and underground cosmogenic neutron spectra with FaNS-2.Keywords
All Related Versions
This publication has 59 references indexed in Scilit:
- First Results from the LUX Dark Matter Experiment at the Sanford Underground Research FacilityPhysical Review Letters, 2014
- Search for Low-Mass Weakly Interacting Massive Particles Using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS ExperimentPhysical Review Letters, 2014
- Dark Matter Results from 225 Live Days of XENON100 DataPhysical Review Letters, 2012
- Results from 730 kg days of the CRESST-II Dark Matter searchThe European Physical Journal C, 2012
- Measurement of the solar neutrino capture rate with gallium metal. III. Results for the 2002–2007 data-taking periodPhysical Review C, 2009
- Determination of theand totalsolar neutrino fluxes using the Sudbury Neutrino Observatory Phase I data setPhysical Review C, 2007
- Neutrino detection with CLEANAstroparticle Physics, 2005
- DIRECT DETECTION OF DARK MATTERAnnual Review of Nuclear and Particle Science, 2004
- BACKGROUNDS TO SENSITIVE EXPERIMENTS UNDERGROUNDAnnual Review of Nuclear and Particle Science, 2004