Efficacy and safety of transcatheter aortic valve implantation in patients with severe bicuspid aortic stenosis
Open Access
- 1 July 2020
- journal article
- research article
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (14) , 873
Abstract
Background: Bicuspid aortic valve (BAV) is common congenital malformation, bicuspid aortic stenosis accounts for a substantial proportion of patients with aortic valve stenosis (AS). Bicuspid AS are more likely to have aortic dilatation with slightly less elliptical annuli, which might lead to paravalvular aortic valve regurgitation (AR) and permanent pacemaker implantation (PPM) after TAVI with higher mortality. Our study aims to understand the therapeutic efficacy and safety of transcatheter aortic valve implantation (TAVI) with a supra-annular structure-based sizing strategy in Chinese AS patients with BAV versus tricuspid aortic valve (TAV). Methods: Seventy-four consecutive tricuspid AS patients and 44 bicuspid AS patients were included and enrolled in the study for analysis. Both groups underwent TAVI performed using balloon sizing less than mild paravalvular AR to assess the proper prosthesis size. The myocardial function within 1 year postoperative were sequentially evaluated using the New York Heart Association (NYHA) class, and echocardiography measurements. The incidence rates of complications at 30 days and 1 year were analyzed. During the 1-year follow-up, the time of death from any cause or complications in both groups was recorded. Results: The study found that the percentage of patients with class III–IV of NYHA dropped after TAVI in both groups, and no significant difference between both groups at 1 year. Compared with the tricuspid AS group patients, Bicuspid group patients had more improvement in mean aortic valve gradient from baseline to 1year (−47.47±13.38 vs. −50.22±19.25 mmHg, PConclusions: TAVI has acceptable therapeutic efficacy and safety and is feasible for AS patients with BAV in China.Keywords
This publication has 35 references indexed in Scilit:
- Supra‐annular structure assessment for self‐expanding transcatheter heart valve size selection in patients with bicuspid aortic valveCatheterization and Cardiovascular Interventions, 2018
- Transapical transcatheter aortic valve implantation using the J-Valve system: A 1-year follow-up studyThe Journal of Thoracic and Cardiovascular Surgery, 2017
- Feasibility, safety, and efficacy of transcatheter aortic valve replacement without balloon predilation: A systematic review and meta‐analysisCatheterization and Cardiovascular Interventions, 2017
- 2-Year Outcomes in Patients Undergoing Surgical or Self-Expanding Transcatheter Aortic Valve ReplacementJACC, 2015
- Aortic Regurgitation After Transcatheter Aortic Valve Implantation With Balloon- and Self-Expandable ProsthesesJACC: Cardiovascular Interventions, 2014
- Outcomes Following Transcatheter Aortic Valve Replacement in the United StatesJAMA, 2013
- Preparatory Balloon Aortic Valvuloplasty During Transcatheter Aortic Valve Implantation for Improved Valve SizingJACC: Cardiovascular Interventions, 2013
- Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve ReplacementJACC, 2013
- Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve ProsthesisJACC: Cardiovascular Interventions, 2010
- Frequency of Bicuspid Aortic Valve in Young Male Conscripts by EchocardiogramThe American Journal of Cardiology, 2005