Electrochemical Diagnostics of Sprayed Fiber-Reinforced Concrete Corrosion
Open Access
- 9 September 2019
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 9 (18) , 3763
Abstract
Sprayed fiber-reinforced concrete is used in construction for the execution and repair of reinforced concrete elements. It is believed that the addition of steel fibers is most effective, due to their parameters and low costs. Some researchers, however, suggest that the addition of steel fibers can contribute to the initiation of corrosion of the main reinforcement. In consideration of the differences of opinion on the corrosion resistance of sprayed fiber-reinforced concrete, it has become necessary to analyze this issue. The article presents comparative studies of corrosion assessments of the main reinforcement in specimens made of ordinary concrete and concrete with steel fibers. The tests were performed using a semi non-destructive galvanostatic pulse method, which allows location of the areas of corrosion and estimation of the reinforcement corrosion activity. In order to initiate the corrosion processes the specimens were subjected to freezing cycles in NaCl solution. In addition, the shrinkage and compressive strength of specimens were measured, and the observation of specimen structure under a scanning microscope was performed. It was found that galvanostatic pulse method allowed estimation of the reinforcement corrosion progress. The corrosion of the main reinforcement in steel fiber reinforced concrete specimens was less advanced than in the specimens without fibers.Keywords
This publication has 17 references indexed in Scilit:
- Durability performance of brine-exposed shotcrete in salt lake environmentConstruction and Building Materials, 2018
- Prediction of reinforcement corrosion due to chloride ingress and its effects on serviceabilityEngineering Structures, 2018
- Mechanical and fracture properties of concrete reinforced with recycled and industrial steel fibers using Digital Image Correlation technique and X-ray micro computed tomographyConstruction and Building Materials, 2018
- Influence of the Air-Entraining Agent in the Concrete Coating on the Reinforcement Corrosion Process in Case of Simultaneous Action of Chlorides and FrostAdvances in Materials Science, 2018
- Corrosion determination of reinforcement using the electrical resistance methodMateriali in tehnologije, 2017
- Effect of Concrete Addition of Selected Micro-fibers on the Reinforcing Bars Corrosion in the Reinforced Concrete SpecimensAdvances in Materials Science, 2016
- Fibre reinforced cement-based (FRC) composites after over 40 years of development in building and civil engineeringComposite Structures, 2008
- Mechanical properties of high-strength steel fiber-reinforced concreteConstruction and Building Materials, 2004
- Chloride-induced corrosion on reinforcing steel: from the fundamentals to the monitoring techniquesCement and Concrete Composites, 2003
- Strength and fracture properties of industrially prepared steel fibre reinforced concreteCement and Concrete Composites, 2002