Reproducibility of Computerized Measurements of QT Interval from Multiple Leads at Rest and During Exercise
- 13 October 2006
- journal article
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 11 (4) , 318-326
Abstract
Background: Accurate measurement of the QT interval is important for diagnosing long QT syndrome (LQTS), and in research on determinants of ventricular repolarization time. We tested automatic analysis of QT intervals from multiple ECG leads on chest. Methods: Eleven healthy volunteers and 10 genotyped LQTS patients were tested at rest and during exercise with a bicycle ergometer twice 1–31 months apart. Electrocardiograms were recorded with the body surface potential mapping system, and 12 precordial channels were selected for analysis. Averaged QT peak and QT end intervals were determined with an automated algorithm, and the difference QT end minus QT peak (Tp‐e) was calculated. Repeatability was assessed by coefficient of variation (CV) between measurements. Results: Within one test at rest the QT end intervals were highly repeatable with CV 0.6%. In repeated tests CV was 4.4% for QT end interval and 3.5% when the QT interval was corrected for heart rate. In exercise test at specified heart rates, mean CV was 3.0% for QT end and 2.9% for QT peak interval. The CV of Tp‐e interval was 10.2% at rest, and 9.3% in exercise test. Reproducibility was comparable between healthy subjects and LQTS patients. Conclusions: The BSPM system with automated analysis produced accurate and highly repeatable QT interval measurements. Reproducibility was adequate also over prolonged time periods both at rest and in exercise stress test. The method can be applied in studying duration of ventricular repolarization time in different physiologic and pharmacologic interventions.Keywords
This publication has 23 references indexed in Scilit:
- Sample Size, Power Calculations, and Their Implications for the Cost of Thorough Studies of Drug Induced QT Interval ProlongationPacing and Clinical Electrophysiology, 2004
- Ambulatory Electrocardiographic Evidence of Transmural Dispersion of Repolarization in Patients With Long-QT Syndrome Type 1 and 2Circulation, 2002
- Congenital and acquired long QT syndromeEuropean Heart Journal, 2000
- The potential for QT prolongation and proarrhythmia by non-antiarrhythmic drugs: clinical and regulatory implications. Report on a Policy Conference of the European Society of CardiologyEuropean Heart Journal, 2000
- Statistics Notes: Measurement errorBMJ, 1996
- Statistics Notes: Measurement error proportional to the meanBMJ, 1996
- T wave “humps” as a potential electrocardiographic marker of the long QT syndromeJACC, 1994
- QT intervals at heart rates from 50 to 120 beats per minute during 24-hour electrocardiographic recordings in 100 healthy men. Effects of atenolol.Circulation, 1992
- The Measurement of the Q-T Interval of the ElectrocardiogramCirculation, 1952
- Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei HerzkrankenActa Medica Scandinavica, 1920