Thermal Neutron SRAM Detector Characterization at the CERN Mixed-Field Facility, CHARM
- 23 April 2018
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 1887-1893
Abstract
The radiation spectra in the CERN Large Hadron Collider (LHC) ranges from gigaelectronvolts down to thermal neutron levels. It is known that the thermal neutrons can significantly affect the electronic devices and systems exposed to the radiation environment of the tunnel and the shielded areas of the LHC. CERN’s radiation monitoring (RadMon) system uses static random access memories (SRAMs) to measure the contributions to the spectrum from both the high-energy hadrons (>20 MeV) and thermal neutrons. The knowledge of the SRAM thermal neutron cross section is required for evaluating their contribution to the particle spectra and thus identifying the thermal neutron critical area. This paper describes a procedure to acquire, by means of RadMon system, the thermal neutron cross section of SRAM memories in a mixed-field environment. The capabilities of the CERN High AcceleRator Mixed-field facility (CHARM) to measure the thermal neutron sensitivity are then investigated. The procedure is evaluated by comparing the thermal neutron cross sections obtained at CHARM and the one measured using a pure thermal neutron beam. The same procedure could be applied to other devices to understand their susceptibility.Keywords
This publication has 7 references indexed in Scilit:
- CHARM: A Mixed Field Facility at CERN for Radiation Tests in Ground, Atmospheric, Space and Accelerator Representative EnvironmentsIEEE Transactions on Nuclear Science, 2016
- Grenoble Large Scale Facilities for Advanced Characterisation of Microelectronics Devices2015
- A New RadMon Version for the LHC and its Injection LinesIEEE Transactions on Nuclear Science, 2014
- Qualification and Characterization of SRAM Memories Used as Radiation Sensors in the LHCIEEE Transactions on Nuclear Science, 2014
- LHC RadMon SRAM Detectors Used at Different Voltages to Determine the Thermal Neutron to High Energy Hadron Fluence RatioIEEE Transactions on Nuclear Science, 2011
- FLUKA Simulations for SEE Studies of Critical LHC Underground AreasIEEE Transactions on Nuclear Science, 2011
- Radiation-induced soft errors in advanced semiconductor technologiesIEEE Transactions on Device and Materials Reliability, 2005