Real‐world evaluation of automated insulin delivery therapy in type 1 diabetes: A multicentre study across regional and metropolitan Queensland, Australia
Open Access
- 28 May 2025
- journal article
- research article
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 27 (8) , 4436-4445
Abstract
Background: Automated insulin delivery (AID) systems, which integrate continuous glucose monitoring (CGM) with automated insulin dosing, have emerged as a transformative therapy. However, real‐world data on AID effectiveness, particularly in regional Australia, remain limited. Methods: We conducted a retrospective audit across three Australian hospital sites—Logan (metropolitan), Mackay and Townsville (regional)—to evaluate the impact of AID therapy in adults with Type 1 Diabetes Mellitus (T1DM). Data on demographics, comorbidities, CGM metrics and clinical outcomes were extracted from medical records and device platforms. The primary outcome was change in HbA1c and CGM time‐in‐range (TIR; 3.9–10 mmol/L) at follow‐up. Follow‐up data were recorded up to 12 months following AID commencement. Secondary outcomes included changes in body weight, glycaemic variability and predictors of HbA1c reduction. Results: The study consisted of 158 people living with T1DM who were initiated on AID. Following AID initiation, mean TIR improved from 53.4% (SD 21.1%) to 70.0% (SD 14.6%) ( p < 0.0001), and time in hyperglycaemia (>13.9 mmol/L) declined from 18.7% (SD 19.4%) to 8.4% (SD 9.31%) ( p < 0.0001). The mean HbA1c significantly decreased from 8.62% (SD 1.70) at baseline to 7.34% (SD 1.31) at follow‐up across the entire study cohort ( p < 0.0001), with 42.7% achieving p < 0.0001) as a significant predictor of HbA1c reduction. Improvements were consistent across AID system types and geographical settings. Conclusions: AID therapy significantly improves glycaemic control in adults with T1DM in both regional and metropolitan Australia. Our findings support the real‐world effectiveness of AID systems and highlight their potential to bridge care gaps across diverse settings.Keywords
This publication has 26 references indexed in Scilit:
- Efficacy and Safety of Different Hybrid Closed Loop Systems for Automated Insulin Delivery in People With Type 1 Diabetes: A Systematic Review and Network Meta‐AnalysisDiabetes/Metabolism Research and Reviews, 2024
- Exploration of barriers and enablers to diabetes care for Aboriginal people on rural Ngarrindjeri CountryHealth Promotion Journal of Australia, 2024
- Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trialThe Lancet Diabetes & Endocrinology, 2024
- A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery SystemsDiabetes Therapy, 2023
- Trial of Hybrid Closed-Loop Control in Young Children with Type 1 DiabetesNew England Journal of Medicine, 2023
- Advanced hybrid closed loop therapy versus conventional treatment in adults with type 1 diabetes (ADAPT): a randomised controlled studyThe Lancet Diabetes & Endocrinology, 2022
- Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 DiabetesNew England Journal of Medicine, 2022
- Metabolic health and vascular complications in type 1 diabetesJournal of Diabetes and its Complications, 2019
- Does the shortage of diabetes specialists in regional and rural Australia matter? Results from Diabetes MILES—AustraliaDiabetes Research and Clinical Practice, 2013
- Complications of Type 1 DiabetesEndocrinology and Metabolism Clinics of North America, 2010