Recently, endoscopic ultrasound (EUS)-guided biliary drainage has been introduced as an alternative method after failed endoscopic biliary drainage, particularly in patients with a pre-existing duodenal obstruction [1] [2] [3]. A longer self-expandable metal stent (SEMS) is usually used for EUS-guided hepaticogastrostomy (EUS-HGS) to prevent stent migration. However, re-intervention after EUS-HGS is challenging because of the protrusion of the SEMS into the stomach. Metal stent trimming using argon plasma coagulation (APC) has been reported to be a useful option for stent-related complications such as dislocation [4] [5]. We report a case in which successful re-intervention after EUS-HGS was made possible by metal stent trimming using APC. A nonagenarian woman with advanced ampullary cancer was admitted to our center. She had a history of endoscopic transpapillary bile duct stenting and duodenal stenting covering the papilla, followed by EUS-HGS with an 8-mm diameter, 12-cm long, silicone-covered nitinol braided stent, with a 1-cm uncovered portion at the proximal end (Niti-S biliary S-type; Taewoong Medical, Seoul, South Korea). The patient developed recurrent cholangitis caused by sludge formation 3 months after HGS. As she showed a good performance status, we attempted therapeutic endoscopic intervention via the HGS site; however, intervention was difficult because of the protrusion of the long SEMS ([Fig. 1]). Therefore, stent trimming was performed with APC using an electrosurgical generator (ICC200; ERBE Elektromedizin, Tübingen, Germany) ([Fig. 2 a, b]; [Video 1]). Subsequently, the fragment of SEMS was removed using grasping forceps through the scope channel ([Fig. 2 c]). Fig. 1 Protrusion into the stomach of the long self-expandable metal stent (SEMS) used for endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS): a on computed tomography (CT) scan; b on endoscopy. Successful bile duct cannulation was achieved using a standard endoscopic retrograde cholangiopancreatography (ERCP) catheter and a 0.025-inch guidewire. The sludge in the bile duct was confirmed on a cholangiogram and was removed with a retrieval balloon catheter ([Fig. 2 d]; [Video 2]). Finally, a 5-Fr straight nasobiliary drainage tube was placed. The procedure was completed without any adverse events. Metal stent trimming using APC may be an effective option for re-intervention after EUS-HGS. Endoscopy_UCTN_Code_TTT_1AR_2AZ