Surface plasmon resonance based fiber optic sensor for the detection of CrO42− using Ag/ITO/hydrogel layers
Authors:
- 19 May 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (14) , 5191-5197
Abstract
Surface plasmon resonance based fiber optic sensor for the detection of CrO4 2− in aqueous samples is reported. The probe is fabricated by coating layers of silver, indium-tin oxide (ITO) and hydrogel with (3-acrylamidopropyl)-trimethylammonium chloride (ATAC) over the unclad core of the optical fiber. The layers of silver and ITO over the unclad core of the fiber are deposited using a thermal evaporation technique, while the hydrogel with ATAC layer is coated using a dip-coating method. For the characterization of the sensor, samples of different concentrations of CrO4 2− are prepared in aqueous solution of sodium chloride. The sensor is based on the principle of shrinkage/swelling of the hydrogel layer when the concentration of the CrO4 2− sample around the hydrogel layer is increased/decreased. The shrinkage of the hydrogel layer occurs because of the polymerization of ATAC present in the hydrogel due to the formation of its ion pair with CrO4 2− anion present in the aqueous solution. The sensor is based on the wavelength interrogation technique. The SPR spectra recorded for different concentrations of CrO4 2− show that as the concentration of CrO4 2− increases the resonance wavelength increases. To achieve the maximum shift in resonance wavelength and the maximum sensitivity of the sensor, the concentrations of ATAC in hydrogel, pH and concentration of sodium chloride in water and the thickness of the ITO layer are optimized. The selectivity of the sensor is investigated using samples of other anions and it is found that the present sensor is more selective for low concentrations of CrO4 2−. The sensor has a low limit of detection and has several advantages, such as immunity to electromagnetic interference, miniaturized probe, low cost, fast response, capability of online monitoring and remote sensing, due to the fabrication of the probe on an optical fiber.Keywords
This publication has 34 references indexed in Scilit:
- Development of an optical fiber SPR sensor for living cell activationBiosensors and Bioelectronics, 2010
- Development of a voltammetric sensor for chromium(VI) determination in wastewater sampleSensors and Actuators B: Chemical, 2007
- Hydrogels in Biology and Medicine: From Molecular Principles to BionanotechnologyAdvanced Materials, 2006
- Detection of CrO42- Using a Hydrogel Swelling Microcantilever SensorAnalytical Chemistry, 2003
- Stress at the Solid−Liquid Interface of Self-Assembled Monolayers on Gold Investigated with a Nanomechanical SensorLangmuir, 2000
- Analysis and storage of samples for chromium determination in seawaterAnalytica Chimica Acta, 1997
- On-line separation and preconcentration of chromium species in seawaterAnalytica Chimica Acta, 1996
- Polymer gels that can recognize and recover moleculesFaraday Discussions, 1995
- Stimuli-responsive polymers: chemical induced reversible phase separation of an aqueous solution of poly(N-isopropylacrylamide) with pendent crown ether groupsPolymer, 1993
- Determination of chromium(III) and chromium(VI) in sea water by atomic absorption spectrometryAnalytica Chimica Acta, 1978