Radar cross section measurements of the human body for UWB radar applications
Authors:
- 1 May 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1290-1293
Abstract
An experimental set-up for mono-static radar cross section measurements in the 1 - 10 GHz frequency band, employing an anechoic chamber, is presented and validated. The test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical metallic and lossy dielectric targets. The set-up is then employed to carry out investigations on the radar cross section of the human body. Initial findings show a complex resonating pattern, highly influenced by even slight subject movements, with a distinct spectral signature for each subject. The final aim is the achievement of realistic scattering data of human subjects for the purpose of designing a ultra wideband (UWB) radar system for breath activity monitoring.Keywords
This publication has 5 references indexed in Scilit:
- A circuit model of an ultra wideband impulse radar system for breath‐activity monitoringInternational Journal of Numerical Modelling: Electronic Networks, Devices and Fields, 2011
- Respiratory System2003
- Automated swept-angle bistatic scattering measurements using continuous wave radarIEEE Transactions on Instrumentation and Measurement, 1992
- Radar cross section of rectangular flat plates as a function of aspect angleIEEE Transactions on Antennas and Propagation, 1966
- Measurement of the Radar Cross Section of a ManProceedings of the IRE, 1958