Usefulness of Extended Holter ECG Monitoring for Serious Arrhythmia Detection in Patients with Heart Failure and Sleep Apnea
- 22 November 2012
- journal article
- research article
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 18 (2) , 163-169
Abstract
Background: In patients with systolic heart failure (HF), coexisting sleep apnea may promote arrhythmia. Ambulatory Holter electrocardiogram (ECG) monitoring (AECG) is a method of arrhythmia and apnea evaluation. We hypothesized that 24‐hour AECG in patients with HF who have a high risk of serious arrhythmia may be less accurate than AECG extended to 48 hours and that, moreover, arrhythmia may be related to apnea.Methods: Eighty‐four recordings of 48‐hour AECG in 84 patients with ischemic HF (mean ejection fraction 34 ± 7%) were analyzed. Day 1, Day 2 were checked for ventricular tachycardia (VT) and supraventricular tachycardia (SVT). Estimated apnea‐hypopnea index (est.AHI) was calculated using Holter, monitoring where est.AHI >15 indicates apnea.Results: In 48‐hour AECG, VT occurred in 34 patients (40.5%) whereas SVT in 17 patients (20.2%), and patients with est.AHI > 15 had higher VT occurrence. In two‐sample one‐sided test for proportions, 24‐hour AECG from Day 1 showed a significantly lower percentage of patients with detected VT than 48‐hour AECG—it was 23.8% (20 patients), meaning a significant underestimation with P = 0.0089. We assessed VT underestimation in the subgroups with regard to est.AHI, and found that it was present in Day 1 monitoring in the subgroups with est.AHI > 15. It was absent in the subgroups with est.AHI ≤ 15 and also in Day 2 monitoring.Conclusions: In patients with systolic HF, 24‐hour AECG may have insufficient sensitivity regarding serious arrhythmia occurrence. If significant apnea was detected in the first day, extending the monitoring may be recommended.Keywords
This publication has 22 references indexed in Scilit:
- Cheyne-Stokes respiration and obstructive sleep apnoea are independent risk factors for malignant ventricular arrhythmias requiring appropriate cardioverter-defibrillator therapies in patients with congestive heart failureEuropean Heart Journal, 2010
- Repeatability of Sleep Apnea Detection in 48‐Hour Holter ECG MonitoringAnnals of Noninvasive Electrocardiology, 2010
- Sleep Disordered Breathing is Associated with Appropriate Implantable Cardioverter Defibrillator Therapy in Congestive Heart Failure PatientsClinical Cardiology, 2010
- Nocturnal Arrhythmias Across a Spectrum of Obstructive and Central Sleep-Disordered Breathing in Older MenArchives of internal medicine (1960), 2009
- Impact of Sleep-Disordered Breathing on Life-Threatening Ventricular Arrhythmia in Heart Failure Patients With Implantable Cardioverter-DefibrillatorThe American Journal of Cardiology, 2008
- Risk Stratification Using Heart Rate Turbulence and Ventricular Arrhythmia in MADIT II: Usefulness and Limitations of a 10‐Minute Holter RecordingAnnals of Noninvasive Electrocardiology, 2004
- Severe bradyarrhythmias in patients with sleep apnoea: the effect of continuous positive airway pressure treatmentA long-term evaluation using an insertable loop recorderEuropean Heart Journal, 2004
- Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoeaIEEE Transactions on Biomedical Engineering, 2003
- Lifetime Risk for Developing Congestive Heart FailureCirculation, 2002
- The duration of Holter monitoring in patients with syncope. Is 24 hours enough?Archives of internal medicine (1960), 1990