Finding the most appropriate technology for building electrodes to be used for long term implants in humans is a challenging issue. What are the most appropriate technologies? How could one achieve robustness, stability, compatibility, efficacy and versatility, for both recording and stimulation? There are no easy answers to these questions as even the most fundamental and apparently obvious factors to be taken into account, such as the necessary mechanical, electrical and biological properties and their interplay, are under debate. We present here our approach along three fundamental parallel pathways: we reduced electrode invasiveness and size without impairing signal-to-noise ratio, we increased electrode active surface area by depositing nanostructured materials and, we protected the brain from direct contact with the electrode without compromising performance. Altogether, these results converge towards high-resolution ECoG arrays that are soft and adaptable to cortical folds, and have been proven to provide high spatial and temporal resolution. This method provides a piece of work which, in our view, makes several steps ahead in bringing such novel devices into clinical settings, opening new avenues in diagnostics of brain diseases and neuroprosthetic applications.Keywords
This publication has 86 references indexed in Scilit:
- Building Biocompatible Hydrogels for Tissue Engineering of the Brain and Spinal CordJournal of Functional Biomaterials, 2012
- Defining and designing polymers and hydrogels for neural tissue engineeringNeuroscience Research, 2012
- Decoding spoken words using local field potentials recorded from the cortical surfaceJournal of Neural Engineering, 2010
- Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkeyFrontiers in Neuroengineering, 2010
- Biomaterial Design Strategies for the Treatment of Spinal Cord InjuriesJournal of Neurotrauma, 2010
- Creating low-impedance tetrodes by electroplating with additivesSensors and Actuators A: Physical, 2009
- Microscale recording from human motor cortex: implications for minimally invasive electrocorticographic brain-computer interfacesNeurosurgical Focus, 2009
- Human neocortical electrical activity recorded on nonpenetrating microwire arrays: applicability for neuroprosthesesNeurosurgical Focus, 2009
- Experimental and theoretical characterization of implantable neural microelectrodes modified with conducting polymer nanotubesBiomaterials, 2008
- Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probesBrain Research, 2007