An unsupervised learning for robust cardiac feature derivation from PPG signals
- 18 October 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2016, 740-743
Abstract
We propose here derivation algorithms for physiological parameters like beat start point, systolic peak, pulse duration, peak-to-peak distance related to heart rate, dicrotic minima, diastolic peak from Photoplethysmogram (PPG) signals robustly. Our methods are based on unsupervised learning mainly following morphology as well as discrete nature of the signal. Statistical learning has been used as a special aid to infer most probable feature values mainly to cope up with presence of noise, which is assumed to be insignificant compared to signal values at each investigation window. Performance of the proposed method is found to be better than other standard methods, yielding precision and sensitivity more than 97% obtained from three real life data sets.Keywords
This publication has 10 references indexed in Scilit:
- A supervised learning approach for the robust detection of heart beat in plethysmographic data2015
- An Assessment of the relationship between dicrotic notch timing and cardiac preload2015
- Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysisPhysiological Measurement, 2014
- On the Analysis of Fingertip Photoplethysmogram SignalsCurrent Cardiology Reviews, 2012
- Study on conditioning and feature extraction algorithm of photoplethysmography signal for physiological parameters detection2011
- An Automatic Beat Detection Algorithm for Pressure SignalsIEEE Transactions on Biomedical Engineering, 2005
- An open-source algorithm to detect onset of arterial blood pressure pulses2003
- Determination of age-related increases in large artery stiffness by digital pulse contour analysisClinical Science, 2002
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Skin photoplethysmography — a reviewComputer Methods and Programs in Biomedicine, 1989