Impact of a Chronic Total Coronary Occlusion on the Incidence of Appropriate Implantable Cardioverter‐Defibrillator Shocks and Mortality: A Substudy of the Dutch Outcome in ICD Therapy (DO‐IT)) Registry
Authors:
- Anna van VeelenAVAnna van Veelen
- Tom E. VerstraelenTVTom E. Verstraelen
- Yvemarie B. O. SomsenYSYvemarie B. O. Somsen
- Marcoen F. ScholtenMSMarcoen F. Scholten
- Lucas V. A. BoersmaLBLucas V. A. Boersma
- Alexander H. MaassAlexander H. Maass
- Sipke StrikwerdaSSSipke Strikwerda
- Mehran FirouziMFMehran Firouzi
- Cornelis P. AllaartCACornelis P. Allaart
Open Access
- 16 April 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (8) , e032033
Abstract
Background: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. Methods and Results: This is a subanalysis of the nationwide Dutch‐Outcome in ICD Therapy (DO‐IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all‐cause mortality and appropriate ICD shocks. Clinical follow‐up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow‐up period of 27 months (interquartile range, 24–32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P =0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03–3.22]; P =0.038). Conclusions: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all‐cause mortality and appropriate ICD shocks.Keywords
This publication has 42 references indexed in Scilit:
- Effect of myocardial scar size on the risk of ventricular arrhythmias in patients with chronic total coronary occlusionInternational Journal of Cardiology, 2023
- Impact of Successful Chronic Coronary Total Occlusion Recanalization on Recurrence of Ventricular Arrhythmias in Implantable Cardioverter-Defibrillator Recipients for Ischemic Cardiomyopathy (VACTO PCI Study)Cardiovascular Revascularization Medicine, 2022
- Increased risk of ventricular arrhythmias in survivors of out-of-hospital cardiac arrest with chronic total coronary occlusionHeart Rhythm, 2018
- Cardiac 123 I- m IBG scintigraphy is associated with freedom of appropriate ICD therapy in stable chronic heart failure patientsInternational Journal of Cardiology, 2017
- Dutch outcome in implantable cardioverter-defibrillator therapy (DO-IT): registry design and baseline characteristics of a prospective observational cohort study to predict appropriate indication for implantable cardioverter-defibrillatorNetherlands Heart Journal, 2017
- Impact of Chronic Total Occlusions and Coronary Revascularization on All-Cause Mortality and the Incidence of Ventricular Arrhythmias in Patients With Ischemic CardiomyopathyThe American Journal of Cardiology, 2015
- Predictors of cardiac death in patients with coronary chronic total occlusion not revascularized by PCIInternational Journal of Cardiology, 2013
- Current Perspectives on Coronary Chronic Total OcclusionsJACC, 2012
- Inappropriate Implantable Cardioverter-Defibrillator ShocksJACC, 2011
- Etiology of sudden death in the community: Results of anatomical, metabolic, and genetic evaluationAmerican Heart Journal, 2010