Silicon micromachined ultrasonic scalpel for the dissection and coagulation of tissue
Authors:
- 8 July 2015
- journal article
- Published by Springer Nature in Biomedical Microdevices
- Vol. 17 (4) , 1-12
Abstract
This work presents a planar, longitudinal mode ultrasonic scalpel microfabricated from monocrystalline silicon wafers. Silicon was selected as the material for the ultrasonic horn due to its high speed of sound and thermal conductivity as well as its low density compared to commonly used titanium based alloys. Combined with a relatively high Young’s modulus, a lighter, more efficient design for the ultrasonic scalpel can be implemented which, due to silicon batch manufacturing, can be fabricated at a lower cost. Transverse displacement of the piezoelectric actuators is coupled into the planar silicon structure and amplified by its horn-like geometry. Using finite element modeling and experimental displacement and velocity data as well as cutting tests, key design parameters have been identified that directly influence the power efficiency and robustness of the device as well as its ease of controllability when driven in resonance. Designs in which the full- and half-wave transverse modes of the transducer are matched or not matched to the natural frequencies of the piezoelectric actuators have been evaluated. The performance of the Si micromachined scalpels has been found to be comparable to existing commercial titanium based ultrasonic scalpels used in surgical operations for efficient dissection of tissue as well as coaptation and coagulation of tissue for hemostasis. Tip displacements (peak-to-peak) of the scalpels in the range of 10–50 μm with velocities ranging from 4 to 11 m/s have been achieved. The frequency of operation is in the range of 50–100 kHz depending on the transverse operating mode and the length of the scalpel. The cutting ability of the micromachined scalpels has been successfully demonstrated on chicken tissue.Keywords
This publication has 28 references indexed in Scilit:
- Piezosurgery in oral and maxillofacial surgeryInternational Journal of Oral and Maxillofacial Surgery, 2011
- Modeling the Tensile Strength and Crack Length of Wire-Sawn Silicon WafersJournal of Solar Energy Engineering, 2009
- Harmonic scalpel versus electrocautery for harvest of radial artery conduits: Reduced risk of spasm and intimal injury on optical coherence tomographyThe Journal of Thoracic and Cardiovascular Surgery, 2008
- High-power low-frequency ultrasound: A review of tissue dissection and ablation in medicine and surgeryJournal of Materials Processing Technology, 2008
- Die operative Therapie des Rhinophyms mit dem ultraschallaktivierten Skalpell (Ultracision Harmonic Scalpel®)Laryngo-Rhino-Otologie, 2003
- Harmonic Scalpel® vs. electrocautery hemorrhoidectomyDiseases of the Colon & Rectum, 2001
- Ultracision®: the harmonic scalpel and its possible uses in maxillofacial surgeryBritish Journal of Oral and Maxillofacial Surgery, 2000
- Posterior Retroperitoneoscopic Partial Adrenalectomy Using Ultrasonic Scalpel for Aldosterone-Producing AdenomaJournal of Endourology, 2000
- Ultrasonically activated scalpel is an effective tool for cutting the pancreas in biliary-pancreatic surgery: experimental and clinical studiesJournal of Hepato-Biliary-Pancreatic Surgery, 2000
- Micromechanical fracture strength of siliconJournal of Applied Physics, 1990