The promise of electrochemical impedance spectroscopy as novel technology for the management of patients with diabetes mellitus
- 6 July 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (18) , 4179-4187
Abstract
Self-monitoring of blood glucose is the standard of care in management of hyperglycemia among patients with diabetes mellitus. To increase the sensitivity and specificity of current devices, a novel method of detecting glucose using electrochemical impedance spectroscopy (EIS) technology is explored. The enzyme glucose oxidase (GOx) was fixed to gold electrodes and a sine wave of sweeping frequencies was induced using a wide range of concentrations of glucose. Each frequency in the impedance sweep was analyzed for the highest response and R-squared value. The frequency with both factors optimized is specific for the glucose–GOx binding interaction and was determined to be 1.17 kHz in purified solutions in both higher and lower ranges of glucose. The correlation between the impedance response and concentration at the low range of detection (0–100 mg dL−1 of glucose) was determined to be 3.53 ohm/ln (mg dL−1) with an R-squared value of 0.90 with a 39 mg dL−1 lower limit of detection. The same frequency of 1.17 kHz was verified in whole blood under the same glucose range. The above data confirm that EIS offers a new method of glucose detection as an alternative to current technology in use by patients. Additionally, the unique frequency response of individual markers allows for modulation of signals so that several other markers important in the management of diabetes could be measured with a single sensor.Keywords
This publication has 20 references indexed in Scilit:
- Diagnosis and Classification of Diabetes MellitusDiabetes Care, 2011
- Development of a novel single sensor multiplexed marker assayThe Analyst, 2011
- Electrochemical SensorsAnalytical Chemistry, 2010
- Label‐Free and Ultra‐Low Level Detection of Salmonella enterica Serovar Typhimurium Using Electrochemical Impedance SpectroscopyElectroanalysis, 2009
- A cytokine immunosensor for Multiple Sclerosis detection based upon label-free electrochemical impedance spectroscopy using electroplated printed circuit board electrodesBiosensors and Bioelectronics, 2009
- Prevalence of interfering substances with point-of-care glucose testing in a community hospitalAmerican Journal of Health-System Pharmacy, 2009
- Electrochemical Biosensors - Sensor Principles and ArchitecturesSensors, 2008
- Label-Free Impedimetric Detection of Glycan−Lectin InteractionsAnalytical Chemistry, 2007
- The application of alkanethiol self-assembled monolayers to enzyme electrodesTrAC Trends in Analytical Chemistry, 1999
- Nanoscaled interdigitated electrode arrays for biochemical sensorsSensors and Actuators B: Chemical, 1998