Comparative ultrasound evaluation of human trabecular bone graft properties after treatment with different sterilization procedures
- 7 January 2009
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 90B (1) , 430-437
Abstract
New sterilization methods for human bone are likely to affect the mechanical properties of human cancellous grafts. These mechanical properties dictate the short‐ and mid‐term results of the orthopedic procedure. The aim of this study was to compare the effects on bone mechanical properties, as assessed by ultrasound velocity, of different sterilization methods used under similar conditions: bleach and sublimation, humid heat, successive baths of physiological saline with osmotic detersion, and CO2 in the supercritical phase. Alterations in mechanical properties were small with CO2 (velocity change: −2%) and humid heat (−2.5%). Osmotic detersion had a significant but moderate effect (−4.7%). The −9% change with the protocol involving bleach suggested a greater than 30% decrease in load to failure, based on earlier studies. Gamma irradiation of defatted trabecular allografts, in a dose of 10 or 25 KGy, produced no significant changes in ultrasound velocity. Powerful protein denaturants used in sterilization protocols substantially alter the mechanical resistance of the grafts, which may jeopardize the orthopedic procedure. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009Keywords
This publication has 26 references indexed in Scilit:
- Biomechanical analysis of allograft bone treated with a novel tissue sterilization processThe Spine Journal, 2006
- Effect of a supercritical CO2 based treatment on mechanical properties of human cancellous boneEuropean Journal of Orthopaedic Surgery & Traumatology, 2005
- A method for the determination of the residual chloroform in defatted cancellous bone transplantsCell and Tissue Banking, 2005
- Gamma irradiation of HIV‐1Journal of Orthopaedic Research, 2001
- Effect of freeze‐drying and gamma irradiation on the mechanical properties of human cancellous boneJournal of Orthopaedic Research, 2000
- Fat in bone xenografts: Importance of the purification procedures on cleanliness, wettability and biocompatibilityBiomaterials, 1993
- Comparison of mechanical properties of human, bovine bone and a new processed bone xenograftBiomaterials, 1993
- Bone allografts sterilised by irradiationInternational Orthopaedics, 1990
- Mechanical Property Distributions in the Cancellous Bone of the Human Proximal FemurActa Orthopaedica, 1980
- Cancellous BoneJournal of Bone and Joint Surgery, 1966