Quantification of Enzymatic Biofilm Removal Using the Sauerbrey Equation: Application to the Case of Pseudomonas protegens
Open Access
- 20 February 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (9) , 10445-10458
Abstract
A methodology for the quantitative analysis of enzymatic removal of biofilms (BF) was developed, based on a quartz crystal microbalance (QCM) under stationary conditions. This was applied to the case of Pseudomonas protegens (PP) BFs, through a series of five enzymes, whose removal activity was screened using the presented methodology. The procedure is based on the following: when BFs can be modeled as rigid materials, QCM can be used as a balance under stationary conditions for determining the BFs mass reduction by enzymatic removal. For considering a BF as a rigid model, energy dissipation effects, associated with viscoelastic properties of the BF, must be negligible. Hence, a QCM system with detection of dissipation (referred to as QCM with dissipation) was used for evaluating the energy losses, which, in fact, resulted in negligible energy losses in the case of dehydrated PP BFs, validating the application of the Sauerbrey equation for the change of mass calculations. The stationary methodology reduces operating times and simplifies data analysis in comparison to dynamic approaches based on flow setups, which requires the incorporation of dissipation effects due to the liquid media. By carrying out QCM, glycosidase-type enzymes showed BF removal higher than 80% at enzyme concentration 50 ppm, reaching removal over 90% in the cases of amylase and cellulase/xylanase enzymes. The highest removal percentage produced a reduction from about 15 to 1 μg in the BF mass. Amylase enzyme was tested from below 50 to 1 ppm, reaching around 60% of removal at 1 ppm. The obtained results were supported by other instrumental techniques such as Raman spectroscopy, attenuated total reflection Fourier transform infrared spectroscopy, atomic force microscopy, high performance anion exchange chromatography, thermogravimetric analysis, and differential scanning calorimetry. The removal quantifications obtained with QCM were compared with those obtained by well-established screening techniques (UV–vis spectrophotometry using crystal violet and agar diffusion test). The proposed methodology expands the possibility of using a quartz microbalance to perform enzymatic activity screening.Keywords
Funding Information
- Consejo Nacional de Investigaciones Científicas y Técnicas (PIP 2021-2023 11220200100993CO, PIP 2021-2023 11220200100410CO)
- Universidad de Buenos Aires (20020190100226BA, 20020190100297BA, 20020190200245BA, 20020150100079BA)
- Ministerio de Ciencia, Tecnología e Innovación (PICT-2020-SERIEA-00710)
- Novozymes Japan
This publication has 65 references indexed in Scilit:
- Gene expression during the development of Mycobacterium smegmatis biofilms on hydroxyapatite surfacesInternational Microbiology, 2023
- A Review of Quartz Crystal Microbalance for Chemical and Biological Sensing ApplicationsSensing and Imaging, 2023
- Population dynamics and crude oil degrading ability of bacterial consortia of isolates from oil-contaminated sites in NigeriaInternational Microbiology, 2021
- Kinetics, Assembling, and Conformation Control of L‐Cysteine Adsorption on Pt Investigated by in situ FTIR Spectroscopy and QCM‐DChemphyschem, 2018
- Is biofilm removal properly assessed? Comparison of different quantification methods in a 96-well plate systemApplied Microbiology and Biotechnology, 2016
- The interaction of cells and bacteria with surfaces structured at the nanometre scaleActa Biomaterialia, 2010
- Biofilm formation and composition on different implant materials in vivoJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2010
- Electrochemical Dictionary2008
- Growing and Analyzing Static BiofilmsCurrent Protocols in Microbiology, 2005
- Verwendung von Schwingquarzen zur W gung d nner Schichten und zur Mikrow gungThe European Physical Journal A, 1959