Submillisievert CT chest for COVID-19 patients in a rural hospital with limited resources
Open Access
- 4 March 2022
- journal article
- research article
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 53 (1) , 1-6
Abstract
Background: This is a secondary analysis of prospectively acquired data approved by the hospital institutional board committee. We performed a retrospective chart review of 463 patients who underwent a CT Chest for suspected COVID-19 infection between April 1st, 2020, and March 31st, 2021. Patients were grouped based on the CT chest obtained protocol: ultra-low dose or full dose. The likelihood of suspicion of COVID-19 infection was classified on a Likert scale based on the probability of pulmonary involvement. For each group, the sensitivity and specificity of CT were compared to nasopharyngeal swab as standard of reference. The median dose length product and duration of apnea were compared between both groups using two-tailed Mann–Whitney U test. The aim of this study is to share our experience of reducing radiation dose in COVID-19 patients by using an ultra-low dose CT chest protocol on a 16 row multidetector CT scan in a hospital with limited resources. Results: Two hundred sixty-nine patients underwent a full dose CT and 194 patients an ultra-low dose CT. In the former group, the median dose length product was 341.11 mGy*cm [Interquartile range (IQR), 239.1–443.2] and the median duration of apnea was 13.29 s [IQR, 10.85–15.73]. In the latter group, the median dose length product was 30.8 mGy*cm [IQR, 28.9–32.7] and median duration of apnea was 8.27 s [IQR, 7.69–8.85]. The sensitivity of the ultra-low dose CT was 91.2% and that of the full dose was 94%. Conclusion: A 90% reduction in estimated dose and 38% reduction in apnea duration could be achieved using an ultra-low dose CT chest protocol on a 16-row MDCT without significant loss in the sensitivity of CT to detect COVID-related parenchymal involvement.Keywords
This publication has 34 references indexed in Scilit:
- Coronavirus Disease 2019 (COVID-19): A Perspective from ChinaRadiology, 2020
- Sensitivity of Chest CT for COVID-19: Comparison to RT-PCRRadiology, 2020
- Chest CT for Typical Coronavirus Disease 2019 (COVID-19) Pneumonia: Relationship to Negative RT-PCR TestingRadiology, 2020
- Clinical Characteristics of Coronavirus Disease 2019 in ChinaThe New England journal of medicine, 2020
- Recommendation of low-dose CT in the detection and management of COVID-2019European Radiology, 2020
- Detection of SARS-CoV-2 in Different Types of Clinical SpecimensJAMA, 2020
- Clinical features of patients infected with 2019 novel coronavirus in Wuhan, ChinaThe Lancet, 2020
- Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image qualityDiagnostic and Interventional Imaging, 2016
- Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the LiverAmerican Journal of Roentgenology, 2012
- Estimating Effective Dose for CT Using Dose–Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy ScanningAmerican Journal of Roentgenology, 2010