Detector technologies for comprehensive two‐dimensional gas chromatography
- 7 August 2006
- journal article
- review article
- Published by Wiley in Journal of Separation Science
- Vol. 29 (12) , 1909-1921
Abstract
The detector is an integral and important part of any chromatographic system. The chromatographic peak profiles (i. e. peak separation) should, ideally, be unaffected by the detector – it should only provide the sensing capacity required at the end of a column separation process. The relatively new technique of comprehensive 2‐D GC (GC×GC) extends the performance of GC manyfold, but comes at a price – existing GC systems may not be adequately designed with the requirements of GC×GC in mind. This is primarily the need for precise measurement of very fast peaks entering the detector (e. g. as fast as 50 ms basewidth in some instances). The capacity of the detector to closely track a rapidly changing chromatographic peak profile depends on a number of factors, such as design of flow paths and make‐up gas introduction, type of detector response mechanism, and the chemistry of the response. These factors are discussed here as a means to appreciate the technical demands of detection in GC×GC. The MS detector will not be included in this review.Keywords
This publication has 60 references indexed in Scilit:
- Analysis of sulfur‐containing compounds in crude oils by comprehensive two‐dimensional gas chromatography with sulfur chemiluminescence detectionJournal of Separation Science, 2004
- Speciation of nitrogen‐containing compounds in diesel fuel by comprehensive two‐dimensional gas chromatographyJournal of Separation Science, 2004
- Comprehensive two‐dimensional gas chromatography (GC×GC) of atropisomeric PCBs, combining a narrow bore β‐cyclodextrin column and a liquid crystal columnJournal of Microcolumn Separations, 2001
- Proper Tuning of Comprehensive Two-Dimensional Gas Chromatography (GC×GC) to Optimize the Separation of Complex Oil FractionsJournal of High Resolution Chromatography, 2000
- Simultaneous Measurement of Hydrocarbons and Sulfur Compounds using Flame Ionization and Sulfur Chemiluminescence Detection for Sulfur Simulated DistillationJournal of High Resolution Chromatography, 1999
- Superior ECD Performance through Design and ApplicationJournal of High Resolution Chromatography, 1999
- Comparison of the SCD and FPD for HRGC determination of atmospheric sulfur gasesJournal of High Resolution Chromatography, 1990
- Column selection and optimization for sulfur compound analyses by gas chromatographyJournal of High Resolution Chromatography, 1990
- Universal sulfur detection by chemiluminescenceAnalytical Chemistry, 1989
- Determination of nitrated polycyclic aromatic hydrocarbons in diesel particulates by gas chromatography with chemiluminescent detectionAnalytical Chemistry, 1984