Performance of an Entrained-Particle Heat Exchanger
Authors:
- 1 October 1996
- journal article
- research article
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 17 (4) , 64-71
Abstract
An experimental investigation was carried out to determine the thermal performance of a heat exchanger operating with vertical upflow of a hot gas loaded with solid particles. Using particles having mean diameters (88-157 μm), the inlet gas velocity was varied from 1.5 to 13 m/s and the inlet temperature was varied from 100 to 600°C. This resulted in mixture densities of 2.0 to 30 kg/m3 for the gas-solid flow. The results showed that thermal performance improved with the addition of solid particles to the gas stream. At a given gas velocity, the gas-side coefficient could be increased by factors of 2 to 4 with the addition of solid particles. The exchanger performance was enhanced with increasing solid loading, decreasing particle size, and increasing gas temperature.Keywords
This publication has 13 references indexed in Scilit:
- Heat transfer from a circulating fluidized bed to membrane waterwall surfacesAIChE Journal, 1987
- Contacting modes and behaviour classification of gas—solid and other two‐phase suspensionsThe Canadian Journal of Chemical Engineering, 1986
- HEAT TRANSFER IN CIRCULATING FLUIDIZED BEDS1986
- Emulsion phase residence time and its use in heat transfer models in fluidized bedsAIChE Journal, 1980
- Types of gas fluidizationPowder Technology, 1973
- Enhancement of Forced Convection Heat Transfer Coefficient Using Detached Turbulence PromotersIndustrial & Engineering Chemistry Process Design and Development, 1967
- Heat Transfer to Pneumatically Conveyed Glass Particles of Fixed SizeJournal of Heat Transfer, 1963
- Heat Transfer in Solids-Gas Transport LinesIndustrial & Engineering Chemistry, 1961
- Heat Transfer to Flowing Gas-Solids Mixtures in a Circular TubeIndustrial & Engineering Chemistry, 1957
- Mechanism of heat transfer to fluidized bedsAIChE Journal, 1955