Parylene C as an Insulating Polymer for Implantable Neural Interfaces: Acute Electrochemical Impedance Behaviors in Saline and Pig Brain In Vitro
Open Access
Abstract
Parylene is used as encapsulating material for medical devices due to its excellent biocompatibility and insulativity. Its performance as the insulating polymer of implantable neural interfaces has been studied in electrolyte solutions and in vivo. Biological tissue in vitro, as a potential environment for characterization and application, is convenient to access in the fabrication lab of polymer and neural electrodes, but there has been little study investigating the behaviors of Parylene in the tissue in vitro. Here, we investigated the electrochemical impedance behaviors of Parylene C polymer coating both in normal saline and in a chilled pig brain in vitro by performing electrochemical impedance spectroscopy (EIS) measurements of platinum (Pt) wire neural electrodes. The electrochemical impedance at the representative frequencies is discussed, which helps to construct the equivalent circuit model. Statistical analysis of fitted parameters of the equivalent circuit model showed good reliability of Parylene C as an insulating polymer in both electrolyte models. The electrochemical impedance measured in pig brain in vitro shows marked differences from that of saline.Keywords
Funding Information
- National Natural Science Foundation of China (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- National Key Research and Development Program of China (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Shanghai Sailing Program (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Science and Technology Commission of Shanghai Municipality (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Opening Project of Zhejiang Lab (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Fudan University-CIOMP Joint Fund (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Opening Project of Shanghai Robot R&D and Transformation Functional Platform (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Ji Hua Laboratory (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
- Shanghai Municipal Science and Technology Major Project (61904038, U1913216, 2021YFC0122702, 2018YFC1705800, 19YF1403600, 19441907600, 19441908200, 19511132000, 2021MC0AB01, FC2019-002, KEH2310024, X190021TB190, X190021TB193, 2021SHZDZX0103, 2018SHZDZX01)
This publication has 53 references indexed in Scilit:
- Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegenerationJournal of Neural Engineering, 2009
- Electrical conductivity of tissue at frequencies below 1 MHzPhysics in Medicine & Biology, 2009
- Impedance characteristics of deep brain stimulation electrodesin vitroandin vivoJournal of Neural Engineering, 2009
- Anodically electrodeposited iridium oxide films microelectrodes for neural microstimulation and recordingSensors and Actuators B: Chemical, 2009
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- Flexible parylene-based multielectrode array technology for high-density neural stimulation and recordingSensors and Actuators B: Chemical, 2008
- Complex impedance spectroscopy for monitoring tissue responses to inserted neural implantsJournal of Neural Engineering, 2007
- Scalable high lead-count parylene package for retinal prosthesesSensors and Actuators B: Chemical, 2006
- A study of intra-cochlear electrodes and tissue interface by electrochemical impedance methods in vivoBiomaterials, 2004
- Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline SolutionJournal of the Electrochemical Society, 1983