Do manual cutting guides for total knee arthroplasty introduce systematic error?
Authors:
- 23 August 2015
- journal article
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (2) , 277-284
Abstract
Conventional cutting guides in total knee arthroplasty can potentially cause unintentional deviation from the planned direction and depth of bone resection resulting in malaligned components. The purpose of this study was therefore to investigate the accuracy of bone cutting jigs for both the femur and tibia using imageless navigation. A total of 125 patients with a mean age of 66.7 ± 9.9 years underwent primary total knee arthroplasty with a Stryker Triathlon™ fixed bearing posterior cruciate retaining implant using imageless navigation. Coronal and sagittal position of the secured cutting jig was recorded and bone resection was checked with a rectangular probe attached to a navigation tracker. There were significant within group differences for the femoral sagittal cut (mean δ = 0.9° [31 %]; p = 0.00001), femoral depth medial compartment (mean δ = 0.5 mm [5 %]; p = 0.001), femoral depth lateral compartment (mean δ = 0.7 mm [7 %]; p = 0.00001), proximal tibial cut (mean δ = 0.3 mm [25 %]; p = 0.001), tibial depth medial compartment (mean δ = 0.6 mm [10 %]; p = 0.0001) and tibia depth lateral cut (mean δ = 0.4 mm [5 %]; p = 0.002). Deviation of more than 2° was observed for the distal cut in the sagittal plane in 17 % and in 9.6 % for the proximal tibial cut in the sagittal plane of all patients. The results of this study demonstrated significant differences between the dialed in cut and “actual” bone resection achieved for all planes for both the femur and tibia. The femur sagittal cut demonstrated a tendency for an extended cut and the tibia showed a tendency for varus.Keywords
This publication has 26 references indexed in Scilit:
- Cutting Error of the Distal Femur in Total Knee Arthroplasty by Use of a Navigation SystemThe Journal of Arthroplasty, 2012
- Residual Varus Alignment does not Compromise Results of TKAs in Patients with Preoperative VarusClinical Orthopaedics and Related Research, 2011
- Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplastyThe Knee, 2010
- The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect?The Knee, 2008
- Cutting errors in total knee replacement: assessment by computer assisted surgeryKnee Surgery, Sports Traumatology, Arthroscopy, 2008
- Randomized Control Trial Comparing Radiographic Total Knee Arthroplasty Implant Placement Using Computer Navigation Versus Conventional TechniqueThe Journal of Arthroplasty, 2005
- Intraoperative cutting errors in total knee arthroplastyArchives of orthopaedic and trauma surgery, 2004
- Critical steps in total knee arthroplastyInternational Orthopaedics, 1995
- Cutting errors in preparation of femoral components in total knee arthroplastyThe Journal of Arthroplasty, 1993
- Surgical instrument design for the accurate cutting of bone for implant fixationClinical Materials, 1992