Abstract
A TiCN–αAl2O3 bilayer coating on a WC–Co substrate is studied to investigate if inelastic strains arise from the chemical vapor deposition process. Both as-deposited and blasted coatings are studied. Due to a mismatch in the coefficients of thermal expansion, tensile residual stresses arise in the coating layers during cooling down to room temperature after deposition, which leads to nucleation of surface cracks. The residual stresses remaining in the coating layers are estimated from X-Ray Diffraction measurements. Nanoindentation is used to determine a hardness value for each coating layer which is adjusted for size effects and then transformed to a representative flow stress using Tabor’s formula. The representative flow stress is found to be an order of magnitude larger than the residual stresses in the coatings, indicating that inelastic deformation during application can be ruled out. SEM-EBSD is used to characterize cross-sections of both as-deposited and blasted coatings. The EBSD maps show no sign of inelastic deformation in the as-deposited coatings, whereas in blasted coatings, only the top layer of Al2O3 show clear evidence of inelastic strains.

This publication has 27 references indexed in Scilit: