MALDI-TOF MS versus VITEK 2 ANC card for identification of anaerobic bacteria
Authors:
Open Access
- 1 May 2014
- journal article
- Vol. 6 (5) , 517-523
Abstract
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an accurate, rapid and inexpensive technique that has initiated a revolution in the clinical microbiology laboratory for identification of pathogens. The Vitek 2 anaerobe and Corynebacterium (ANC) identification card is a newly developed method for identification of corynebacteria and anaerobic species. The aim of this study was to evaluate the effectiveness of the ANC card and MALDI-TOF MS techniques for identification of clinical anaerobic isolates. Five reference strains and a total of 50 anaerobic bacteria clinical isolates comprising ten different genera and 14 species were identified and analyzed by the ANC card together with Vitek 2 identification system and Vitek MS together with version 2.0 database respectively. 16S rRNA gene sequencing was used as reference method for accuracy in the identification. Vitek 2 ANC card and Vitek MS provided comparable results at species level for the five reference strains. Of 50 clinical strains, the Vitek MS provided identification for 46 strains (92%) to the species level, 47 (94%) to genus level, one (2%) low discrimination, two (4%) no identification and one (2%) misidentification. The Vitek 2 ANC card provided identification for 43 strains (86%) correct to the species level, 47 (94%) correct to the genus level, three (6%) low discrimination, three (6%) no identification and one (2%) misidentification. Both Vitek MS and Vitek 2 ANC card can be used for accurate routine clinical anaerobe identification. Comparing to the Vitek 2 ANC card, Vitek MS is easier, faster and more economic for each test. The databases currently available for both systems should be updated and further developed to enhance performance.Keywords
This publication has 24 references indexed in Scilit:
- Identification of Anaerobic Bacteria by Bruker Biotyper Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry with On-Plate Formic Acid PreparationJournal of Clinical Microbiology, 2013
- A comparison of Api 20A vs MALDI-TOF MS for routine identification of clinically significant anaerobic bacterial strains to the species levelJournal of Microbiological Methods, 2013
- Use of MALDI-TOF mass spectrometry for identification of bacteria that are difficult to cultureJournal of Microbiological Methods, 2013
- Prospective Evaluation of a Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System in a Hospital Clinical Microbiology Laboratory for Identification of Bacteria and Yeasts: a Bench-by-Bench Study for Assessing the Impact on Time to Identification and Cost-EffectivenessJournal of Clinical Microbiology, 2012
- Comparison of two matrix-assisted laser desorption ionisation-time of flight mass spectrometry methods for the identification of clinically relevant anaerobic bacteriaClinical Microbiology and Infection, 2011
- Evaluation of the Vitek 2 ANC Card for Identification of Clinical Isolates of Anaerobic BacteriaJournal of Clinical Microbiology, 2011
- Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identificationClinical Microbiology and Infection, 2010
- Evaluation of the New Vitek 2 ANC Card for Identification of Medically Relevant Anaerobic BacteriaJournal of Clinical Microbiology, 2009
- Multicenter Evaluation of the Vitek 2 Anaerobe and Corynebacterium Identification CardJournal of Clinical Microbiology, 2008
- Impact of 16S rRNA Gene Sequence Analysis for Identification of Bacteria on Clinical Microbiology and Infectious DiseasesClinical Microbiology Reviews, 2004