Mechanics of Three-Dimensional Printed Lattices for Biomedical Devices
Authors:
- 14 January 2019
- journal article
- research article
- Published by Wiley in Journal of Mechanical Design
- Vol. 141 (3)
Abstract
Advances in three-dimensional (3D) printing are enabling the design and fabrication of tailored lattices with high mechanical efficiency. Here, we focus on conducting experiments to mechanically characterize lattice structures to measure properties that inform an integrated design, manufacturing, and experiment framework. Structures are configured as beam-based lattices intended for use in novel spinal cage devices for bone fusion, fabricated with polyjet printing. Polymer lattices with 50% and 70% porosity were fabricated with beam diameters of 0.4–1.0mm, with measured effective elastic moduli from 28MPa to 213MPa. Effective elastic moduli decreased with higher lattice porosity, increased with larger beam diameters, and were highest for lattices compressed perpendicular to their original build direction. Cages were designed with 50% and 70% lattice porosities and included central voids for increased nutrient transport, reinforced shells for increased stiffness, or both. Cage stiffnesses ranged from 4.1kN/mm to 9.6kN/mm with yielding after 0.36–0.48mm displacement, thus suggesting their suitability for typical spinal loads of 1.65kN. The 50% porous cage with reinforced shell and central void was particularly favorable, with an 8.4kN/mm stiffness enabling it to potentially function as a stand-alone spinal cage while retaining a large open void for enhanced nutrient transport. Findings support the future development of fully integrated design approaches for 3D printed structures, demonstrated here with a focus on experimentally investigating lattice structures for developing novel biomedical devices.Keywords
This publication has 62 references indexed in Scilit:
- Activities of Everyday Life with High Spinal LoadsPLOS ONE, 2014
- Porous Biodegradable Lumbar Interbody Fusion Cage Design and Fabrication Using Integrated Global-Local Topology Optimization With Laser SinteringJournal of Biomechanical Engineering, 2013
- Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturingMaterials & Design (1980-2015), 2013
- Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysisBMC Musculoskeletal Disorders, 2013
- Finite element modelling of the compressive response of lattice structures manufactured using the selective laser melting techniqueInternational Journal of Mechanical Sciences, 2013
- Comparative anatomical dimensions of the complete human and porcine spineEuropean Spine Journal, 2010
- A mathematical approach to bone tissue engineeringPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2009
- Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques – a three-dimensional finite element analysisBMC Musculoskeletal Disorders, 2008
- The properties of foams and latticesPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2005
- Finite element modeling concepts and linear analyses of 3D regular open cell structuresJournal of Materials Science, 2005