Experimental Analysis of CO2 Concentration Changes in an Apartment Using a Residential Heat Recovery Ventilator
Open Access
- 15 September 2021
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10302
Abstract
Korean law requires at least three levels of control for apartment ventilation systems, including 0.5 air change per hour (ACH). When this law was enacted, it was believed that a 0.5 ACH air flow rate would be sufficient for apartments following building completion. However, ventilation systems cause different air qualities in each space within a unit, depending on infiltration rate and number of occupants. In addition, the current ventilation rate standard is based on an apartment unit’s total area, assuming that all room doors are open. In this study, changes in CO2 concentration were experimentally analyzed based on the number of occupants and various ventilation frequencies with closed doors to analyze air quality differences among rooms in a typical 85 m2 apartment unit in Korea. When the 0.5 ACH ventilation was performed, maintaining 1000 ppm or less was difficult if four people stayed for more than two hours in the living room or two people stayed for more than one hour in the bedroom with closed doors. Our results indicate that it is challenging to maintain a CO2 concentration of 1000 ppm when doors are closed as standards are calculated based on a unit’s total area. Therefore, ventilation systems should be required to provide different air volumes for each room.Keywords
Funding Information
- Ministry of Trade, Industry and Energy (20009795)
This publication has 8 references indexed in Scilit:
- A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and SummerKIEAE Journal, 2017
- An Analysis on HCHO, TVOC, CO2 Concentration of Existing-Housing Indoor-Air in SummerKIEAE Journal, 2016
- Demand-controlled ventilation in new residential buildings: Consequences on indoor air quality and energy savingsIndoor and Built Environment, 2013
- Energy saving potential and repercussions on indoor air quality of demand controlled residential ventilation strategiesBuilding and Environment, 2011
- Optimization of Occupancy Based Demand Controlled Ventilation in ResidencesInternational Journal of Ventilation, 2011
- Energy efficient demand controlled ventilation in single family housesEnergy and Buildings, 2010
- Numerical study of a hybrid ventilation system for single family housesSolar Energy, 2007
- Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windowsJournal of Exposure Science & Environmental Epidemiology, 2002