Hydrogen Peroxide-Based Gas Generator Design and Performance Testing as an Aircraft Emergency Power Unit
- 12 August 2010
- journal article
- research article
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 132 (11) , 114504
Abstract
Hydrazine monopropellant is often used with a spontaneous catalyst a high-performance aircraft emergency power unit (EPU) and in aerospace propulsion; however, it is toxic and requires special handling. A hydrogen peroxide -based gas generator, which is suitable for a new family of environmentally friendly monopropellants and is a substitute for toxic hydrazine in EPUs, is introduced in this study. A catalyst for decomposition, superior to silver catalysts at normal starting and reactivity capabilities, was selected and developed. The performance tests of coupling the gas generator with a turbocharger showed acceptable results for an aircraft EPU with decomposition above 90%, 37 kW maximum turbine output power, and a maximum starting delay of 1.2 s during normal starting operation. The gas generator also demonstrated satisfactory performance during repeated pulse operation at a pulse duration of 3 s and 60 s under various output conditions.
Keywords
This publication has 9 references indexed in Scilit:
- Pulse Response Times of Hydrogen Peroxide Monopropellant Thrusters2009
- Firing Performance of Advanced Hydrogen Peroxide Catalytic Beds in a Monopropellant Thruster Prototype2008
- Design and Development of a Sub-Scale Nitrous Oxide Monopropellant Gas Generator2007
- Reaction Balance of Thermal and Catalytic Decomposition of Nitrogen-Based Ionic Monopropellant2007
- Novel Concepts for an Advanced Non-Toxic Gas Generator2006
- Advanced Emergency Power System Using Thermal Battery for Future Aircraft2006
- Long Term Storability of Hydrogen Peroxide2005
- Recent developments in aircraft emergency power2000
- The use of hydrogen peroxide for propulsion and power1999