Comparison of Two New Generation Pulse Oximeters with Arterial Oxygen Saturation in Critically Ill Children
Authors:
- 15 March 2014
- journal article
- research article
- Published by Springer Nature in Indian Journal of Pediatrics
- Vol. 81 (12) , 1297-1301
Abstract
To compare the performance of two new generation pulse oximeters, one with enhanced signal extraction technology (SET) and other without enhanced SET in detecting hypoxemia and to correlate it with arterial blood gas analysis. Forty-eight patients, admitted to pediatric intensive care unit (PICU) of a teritiary care teaching hospital in India for critical care and support during the study period, who had an arterial catheter in situ were included. Children with those disease conditions known to interfere with pulse oximetry and blood gas analysis were excluded.184 set of observations were made during the study period. Each set had oxygen saturation (SpO2) measured from both the pulse oximeters and the corresponding arterial oxygen saturation (SaO2). The values were compared for occurrence of true and false alarms during periods of normal BP, hypotension and varying degrees of hypoxia. The mean arterial SaO2 in the study was 94.4 % ± 4.9. The mean SpO2 recorded in conventional and enhanced signal extraction technology (SET) pulse oximeters were 94.9 % ± 4.5 and 97.2 % ± 4.7 respectively. Enhanced signal extraction technology pulse oximeter detected 4/27 (15 %) of true hypoxemic events and 1 event was a false alarm. Conventional pulse oximeter detected 11/27 (41 %) true hypoxemic events but recorded 6 false alarms. Both pulse oximeters were not found to be performing satisfactorily in picking up hypoxemia in the study. There was good correlation with mean SpO2 from pulse oximeters and arterial SaO2. The reliability of pulse oximetry decreases with worsening hypoxemia and hypotension, and the sensitivity for picking up hypoxemia can be as low as 15 %.Keywords
This publication has 13 references indexed in Scilit:
- Oxygen Saturation and Outcomes in Preterm InfantsNew England Journal of Medicine, 2013
- Does Ambient Light Affect the Accuracy of Pulse Oximetry?Respiratory Care, 2003
- The Effects of Motion Artifact and Low Perfusion on the Performance of a New Generation of Pulse Oximeters in Volunteers Undergoing HypoxemiaRespiratory Care, 2002
- Differences in pulse oximetry technology can affect detection of sleep-disorderd breathing in children.2002
- Masimo Signal Extraction Pulse OximetryJournal of Clinical Monitoring and Computing, 2000
- Influence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery roomBritish Journal of Anaesthesia, 1997
- The Pulse Oximetry Gap in Carbon Monoxide IntoxicationAnnals of Emergency Medicine, 1994
- Effects of Methemoglobinemia on Pulse Oximetry and Mixed Venous OximetryAnesthesiology, 1989
- LIMITATIONS OF PULSE OXIMETRYThe Lancet, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986