Vascular Enhancement and Image Quality of MDCT Pulmonary Angiography in 400 Cases: Comparison of Standard and Low Kilovoltage Settings
Authors:
- Shin MatsuokaSMShin Matsuoka
- Andetta R. HunsakerAHAndetta R. Hunsaker
- Ritu R. GillRGRitu R. Gill
- Isabel B. OlivaIOIsabel B. Oliva
- Beatrice Trotman-DickensonBTBeatrice Trotman-Dickenson
- Francine L. JacobsonFJFrancine L. Jacobson
- Hiroto HatabuHHHiroto Hatabu
- 1 June 2009
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (6) , 1651-1656
Abstract
OBJECTIVE. The purpose of this study was to investigate the vascular enhancement and image quality of pulmonary CT angiography performed with lower peak kilovoltage settings in a large patient sample.MATERIALS AND METHODS. This retrospective study was approved by our institutional review board, which waived the requirement for informed consent. Four hundred patients believed to have a pulmonary embolism were studied. All patients underwent 16- or 64-MDCT with automatic tube current modulation. The 200 patients in the standard peak kilovoltage group (mean age, 57 years; range, 22–95 years) underwent MDCT at 130 or 120 kVp. The 200 patients in the low peak kilovoltage group (mean age, 56 years; range, 21–92 years) underwent MDCT at 110 or 100 kVp. Vascular enhancement was evaluated by measurement of the attenuation value in the main pulmonary artery and segmental and subsegmental arteries. Image noise was quantified by measurement of the SD of the attenuation value in the main pulmonary artery. One blinded ...Keywords
This publication has 27 references indexed in Scilit:
- Modelling the effect of lead and other materials for shielding of the fetus in CT pulmonary angiographyBritish Journal of Radiology, 2008
- Utilization Patterns and Diagnostic Yield of 3421 Consecutive Multidetector Row Computed Tomography Pulmonary Angiograms in a Busy Emergency DepartmentJournal of Computer Assisted Tomography, 2008
- Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current ModulationAmerican Journal of Roentgenology, 2008
- Image Quality and Radiation Exposure at Pulmonary CT Angiography with 100- or 120-kVp Protocol: Prospective Randomized StudyRadiology, 2007
- CT Pulmonary Angiography versus Ventilation-Perfusion Scintigraphy in Pregnancy: Implications from a UK Survey of Doctors' Knowledge of Radiation ExposureRadiology, 2006
- Incidence of Pulmonary Embolism in Younger Versus Older Patients Using CTJournal of Thoracic Imaging, 2006
- Radiation Dose to the Fetus from Body MDCT During Early GestationAmerican Journal of Roentgenology, 2006
- Multidetector-Row Computed Tomography in Suspected Pulmonary EmbolismNew England Journal of Medicine, 2005
- Pulmonary Embolism in Pregnant Patients: A Survey of Practices and Policies for CT Pulmonary AngiographyAmerican Journal of Roentgenology, 2003
- In-Plane Bismuth Breast Shields for Pediatric CT: Effects on Radiation Dose and Image Quality Using Experimental and Clinical DataAmerican Journal of Roentgenology, 2003