Fast MR parameter mapping using k‐t principal component analysis
Open Access
- 9 March 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (3) , 706-716
Abstract
Quantification of magnetic resonance parameters plays an increasingly important role in clinical applications, such as the detection and classification of neurodegenerative diseases. The major obstacle that remains for its widespread use in clinical routine is the long scanning times. Therefore, strategies that allow for significant decreases in scan time are highly desired. Recently, the k‐t principal component analysis method was introduced for dynamic cardiac imaging to accelerate data acquisition. This is done by undersampling k‐t space and constraining the reconstruction of the aliased data based on the k‐t Broad‐use Linear Acquisition Speed‐up Technique (BLAST) concept and predetermined temporal basis functions. The objective of this study was to investigate whether the k‐t principal component analysis concept can be adapted to parameter quantification, specifically allowing for significant acceleration of an inversion recovery fast imaging with steady state precession (TrueFISP) acquisition. We found that three basis functions and a single training data line in central k‐space were sufficient to achieve up to an 8‐fold acceleration of the quantification measurement. This allows for an estimation of relaxation times T1 and T2 and spin density in one slice with sub‐millimeter in‐plane resolution, in only 6 s. Our findings demonstrate that the k‐t principal component analysis method is a potential candidate to bring the acquisition time for magnetic resonance parameter mapping to a clinically acceptable level. Magn Reson Med, 2011.Keywords
Funding Information
- BayStMWIVT
This publication has 23 references indexed in Scilit:
- A new window in multiple sclerosis pathology: non-conventional quantitative magnetic resonance imaging outcomesJournal of the Neurological Sciences, 2009
- T1 mapping using spoiled FLASH‐EPI hybrid sequences and varying flip anglesMagnetic Resonance in Medicine, 2009
- Rapid magnetic resonance quantification on the brain: Optimization for clinical usageMagnetic Resonance in Medicine, 2008
- Novel method for rapid, simultaneous T1, T*2, and proton density quantificationMagnetic Resonance in Medicine, 2007
- MR properties of excised neural tissue following experimentally induced demyelinationNMR in Biomedicine, 2005
- High‐resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2Magnetic Resonance in Medicine, 2004
- Inversion recovery TrueFISP: Quantification of T1, T2, and spin densityMagnetic Resonance in Medicine, 2004
- Quantitative MRI of the Brain2003
- T1 and T2 in the Brain of Healthy Subjects, Patients with Parkinson Disease, and Patients with Multiple System Atrophy: Relation to Iron ContentRadiology, 1999
- A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?Medical Physics, 1987