Dynamic Computed Tomography of the Neonatal Lung
Authors:
- Thomas ElgetiTEThomas Elgeti
- Hans ProquittéHPHans Proquitté
- Noga E. RogallaNRNoga E. Rogalla
- Jürgen MewsJMJürgen Mews
- Roland WauerRWRoland Wauer
- Bernd HammBHBernd Hamm
- Gerd SchmalischGSGerd Schmalisch
- Patrik RogallaPRPatrik Rogalla
- 1 December 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (12) , 761-765
Abstract
The purpose of this study was to evaluate and validate dynamic volume calculation by respiratory-gated multislice computed tomography (CT) in small neonatal animals. Six mechanically ventilated newborn piglets were imaged in a multislice CT with 0.5-mm slice thickness (4:16 pitch, 0.5-second rotation time, 120 kV). The respirator was connected to the CT unit for recording the respiratory signal. Simultaneously, tidal volume was measured by the respirator and functional residual capacity (FRC) using a multiple-breath washin-washout technique (MBW) with heptafluoropropane (HFP) as tracer gas. Complete volume datasets were reconstructed throughout the respiratory cycle in increments of 10% using retrospective half-scan gating. All animals were scanned in 3 different ventilator settings. Dynamic lung volumes (tidal volumes) were calculated by means of segmentation of the lung parenchyma during the respiratory cycle using work-in-progress software. The mean (+/-standard deviation) FRC determined by CT was 24.7+/-8.6 mL versus 24.8+/-7.3 mL for the MBW technique. There was no statistically significant difference (P=0.555). Pearson's correlation coefficient showed a strong correlation between the data obtained with CT and that obtained with the MBW technique (r=0.886). After exclusion of one outlier, tidal volumes showed a similar correlation (r=0.837) without significant differences in the mean values (CT: 8.9+/-2.4 mL and respirator: 8.7+/-2.4 mL, P=0.566). Dynamic multislice CT with respiratory gating allows for calculation of lung volumes and may be useful for future CT applications in human neonatal lung imaging.Keywords
This publication has 31 references indexed in Scilit:
- Feasibility of Pulmonary Ventilation Visualization With Aerosolized Magnetic Resonance Contrast MediaInvestigative Radiology, 2005
- Dynamic Assessment of Tracheal Stenosis Due to Double Aortic Arch Using Low-Dose, 16-Slice Computed TomographyCirculation, 2004
- Mehrschicht-Spiral-CT (MSCT) in der Kinderradiologie: Dosisreduktion bei der Untersuchung von Thorax und AbdomenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Quantifizierung von Atelektasen bei kontrollierter Beatmung: Spiral-CT versus dynamische Einzelschicht-CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Evaluation of Chest Motion and Volumetry During the Breathing Cycle by Dynamic MRI in Healthy SubjectsInvestigative Radiology, 2004
- Quantifizierung von Atelektasen bei kontrollierter Beatmung: Spiral-CT versus dynamische Einzelschicht-CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Computerunterstützte Diagnostik in der Thoraxradiologie - aktuelle Schwerpunkte und TechnikenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Radiology in the Intensive Care Unit (Part 2)Journal of Intensive Care Medicine, 2003
- CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Lung Volumes and Pressure-Volume Relations of the Respiratory System in Small Ventilated Neonates with Severe Respiratory Distress SyndromePediatric Research, 1996