Ultrashort-Echo-Time MRI of the Disco-Vertebral Junction: Modulation of Image Contrast via Echo Subtraction and Echo Times
Open Access
Abstract
Introduction: The disco-vertebral junction (DVJ) of the lumbar spine contains thin structures with short T2 values, including the cartilaginous endplate (CEP) sandwiched between the bony vertebral endplate (VEP) and the nucleus pulposus (NP). We previously demonstrated that ultrashort-echo-time (UTE) MRI, compared to conventional MRI, is able to depict the tissues at the DVJ with improved contrast. In this study, we sought to further optimize UTE MRI by characterizing the contrast-to-noise ratio (CNR) of these tissues when either single echo or echo subtraction images are used and with varying echo times (TEs). Methods: In four cadaveric lumbar spines, we acquired 3D Cones (a UTE sequence) images at varying TEs from 0.032 ms to 16 ms. Additionally, spin echo T1- and T2-weighted images were acquired. The CNRs of CEP-NP and CEP-VEP were measured in all source images and 3D Cones echo subtraction images. Results: In the spin echo images, it was challenging to distinguish the CEP from the VEP, as both had low signal intensity. However, the 3D Cones source images at the shortest TE of 0.032 ms provided an excellent contrast between the CEP and the VEP. As the TE increased, the contrast decreased in the source images. In contrast, the 3D Cones echo subtraction images showed increasing CNR values as the second TE increased, reaching statistical significance when the second TE was above 10 ms (p < 0.05). Conclusions: Our study highlights the feasibility of incorporating UTE MRI for the evaluation of the DVJ and its advantages over conventional spin echo sequences for improving the contrast between the CEP and adjacent tissues. Additionally, modulation of the contrast for the target tissues can be achieved using either source images or subtraction images, as well as by varying the echo times.Keywords
Funding Information
- NIH NIAMS (AR066622)
- General Electric Healthcare for MRI (AR066622)
This publication has 32 references indexed in Scilit:
- High contrast cartilaginous endplate imaging in spine using three dimensional dual-inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequenceSkeletal Radiology, 2023
- Ultrashort time-to-echo MR morphology of cartilaginous endplate correlates with disc degeneration in the lumbar spineEuropean Spine Journal, 2023
- Evaluation of the disco-vertebral junction using ultrashort time-to-echo magnetic resonance imaging: inter-reader agreement and association with vertebral endplate lesionsSkeletal Radiology, 2016
- Evaluation of intervertebral disc cartilaginous endplate structure using magnetic resonance imagingEuropean Spine Journal, 2013
- MRI with zero echo time: Hard versus sweep pulse excitationMagnetic Resonance in Medicine, 2011
- Double half RF pulses for reduced sensitivity to eddy currents in UTE imagingMagnetic Resonance in Medicine, 2009
- Acquisition‐weighted stack of spirals for fast high‐resolution three‐dimensional ultra‐short echo time MR imagingMagnetic Resonance in Medicine, 2008
- In vivo MRI of submillisecond T2 species with two‐dimensional and three‐dimensional radial sequences and applications to the measurement of cortical bone waterNMR in Biomedicine, 2007
- Water‐ and fat‐suppressed proton projection MRI (WASPI) of rat femur boneMagnetic Resonance in Medicine, 2007
- Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted samplingMagnetic Resonance in Medicine, 2006