Inferior Vena Cava Diameter and Left Atrial Diameter Measure Volume but Not Dry Weight
Authors:
- Rajiv AgarwalRARajiv Agarwal
- J. Michael BouldinJBJ. Michael Bouldin
- Robert P. LightRLRobert P. Light
- Ashok GargAGAshok Garg
- 1 May 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Journal of the American Society of Nephrology
- Vol. 6 (5) , 1066-1072
Abstract
Summary: Background and objectives: Hypervolemia is an important and modifiable cause of hypertension. Hypertension improves with probing dry weight, but its effect on echocardiographic measures of volume is unknown. Design, setting, participants, & measurements: Shortly after dialysis, echocardiograms were obtained at baseline and longitudinally every 4 weeks on two occasions. Among 100 patients in the additional ultrafiltration group, 198 echocardiograms were performed; among 50 patients in the control group, 104 echocardiograms were performed. Results: Baseline inferior vena cava (IVC)insp diameter was approximately 5.1 mm/m2; with ultrafiltration, change in IVCinsp diameter was −0.95 mm/m2 more compared with the control group at 4 weeks and −1.18 mm/m2 more compared with the control group at 8 weeks. From baseline IVCexp diameter of approximately 8.2 mm/m2, ultrafiltration-induced change at 4 weeks was −1.06 mm/m2 more and at 8 weeks was −1.07 mm/m2 more (P = 0.044). From a baseline left atrial diameter of 2.1 cm/m2, ultrafiltration-induced change at 4 weeks was −0.14 cm/m2 more and at 8 weeks was −0.15 cm/m2 more. At baseline, there was no relationship between interdialytic ambulatory BP and echocardiographic parameters of volume. The reduction in interdialytic ambulatory BP was also independent of change in the echocardiographic volume parameters. Conclusions: The inferior vena cava and left atrial diameters are echocardiographic parameters that are responsive to probing dry weight; thus, they reflect excess volume. However, echocardiographic volume parameters are poor determinants of interdialytic BP, and their change does not predict the BP response to probing dry weight.Keywords
This publication has 15 references indexed in Scilit:
- Hypervolemia Is Associated With Increased Mortality Among Hemodialysis PatientsHypertension, 2010
- Relative Plasma Volume Monitoring During Hemodialysis Aids the Assessment of Dry WeightHypertension, 2010
- Opinion: Can Chronic Volume Overload Be Recognized and Prevented in Hemodialysis Patients?Seminars in Dialysis, 2009
- Volume-Associated Ambulatory Blood Pressure Patterns in Hemodialysis PatientsHypertension, 2009
- Dry-Weight Reduction in Hypertensive Hemodialysis Patients (DRIP)Hypertension, 2009
- On the Importance of Pedal Edema in Hemodialysis PatientsClinical Journal of the American Society of Nephrology, 2008
- Left Atrial Volume Monitoring and Cardiovascular Risk in Patients with End-Stage Renal DiseaseJournal of the American Society of Nephrology, 2007
- Handcarried Ultrasound Measurement of the Inferior Vena Cava for Assessment of Intravascular Volume Status in the Outpatient Hemodialysis ClinicClinical Journal of the American Society of Nephrology, 2006
- Relation of Mean Right Atrial Pressure to Echocardiographic and Doppler Parameters of Right Atrial and Right Ventricular FunctionCirculation, 1996
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978