Objective. To determine whether enchondromas and chondrosarcomas can be differentiated on the basis of peritumoral MR signal abnormality. Design. STIR and T2-weighted MRI images were retrospectively assessed for the presence and extent of abnormal peritumoral marrow and soft-tissue signal. The cause of the peritumoral signal abnormality was determined by histologic correlation with resection specimens. The presence or absence of bone destruction was noted. Patients. Twenty-three patients were studied: ten with enchondromas (three men, seven women; ages 33–73 years) and 13 with chondrosarcomas (seven men, six women; ages 25–88 years). Results. Abnormal peritumoral marrow signal was present on STIR images around none of 10 enchondromas and all of 13 chondrosarcomas (P0.04). In the subset of tumors without bone destruction, peritumoral marrow signal abnormality was present around none of ten enchondromas and all of five chondrosarcomas (P=0.0003); abnormal soft-tissue signal was present around none of ten enchondromas and two of five chondrosarcomas (P>0.05). Conclusion. Abnormal marrow or soft-tissue signal around a chondroid tumor is suggestive of chondrosarcoma, even in the absence of bone destruction. STIR images are necessary for adequate detection of peritumoral signal abnormalities.