Transient Absorption of Inhaled Vapors into a Multilayer Mucus–Tissue–Blood System
- 14 October 2009
- journal article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (2) , 517-536
Abstract
Previous studies have approximated the absorption of vapors into the walls of the respiratory tract as a steady state process. However, non-dimensional analysis indicates that the absorption of vapors in the conducting airways is time-dependent over the timescale of a breathing cycle. The objective of this study was to evaluate the mass transport of sample chemical species through a simple multilayer system composed of mucus, tissue, and blood components on a transient basis. Individual multilayer models were considered that represent the wall dimensions of the nasal extrathoracic (ET2), bronchial (BB), and bronchiolar (bb) airways. Sample vapors considered were acetaldehyde and benzene, which are highly soluble and moderately soluble in mucus, respectively. To determine absorption, mass transport was calculated based on an existing analytical steady state solution, a new analytical transient solution, and a numerical transient solution. Results indicated that concentrations within the mucus and tissue layers were highly time dependent in the ET2 and BB regions and moderately time dependent in the bb airways over the timescale of an inhalation cycle, which is approximately 1–2 s. Fluxes of vapors into the tissue and blood varied with time for approximately 6–8 s in the BB region and 0.6–0.8 s in the bb model. The associated transient blood uptake of acetaldehyde and benzene in the upper ET2 and BB regions varied from steady state values by a factor of approximately 30 after 1 s. Under similar conditions, transient uptake in the bb model varied from steady state conditions by a factor of approximately 1.3. Surprisingly, inclusion of chemical reactions in the mucus and tissue modified the transient uptake predictions only for very large values of reaction rate coefficients (K > 100 min−1). In summary, transient effects significantly impact the absorption of vapors into the walls of the upper respiratory tract (ET2 and BB regions) and may largely diminish the effects of chemical reactions over the timescale of an inhalation cycle. Furthermore, the transient analytical solution that was developed provides the basis for an improved boundary condition in future CFD simulations of air-phase transport and wall absorption.Keywords
This publication has 32 references indexed in Scilit:
- A mathematical model for the absorption and metabolism of formaldehyde vapour by humansToxicology and Applied Pharmacology, 2005
- Modeling Soluble Gas Exchange in the Airways and AlveoliAnnals of Biomedical Engineering, 2003
- Application of a Hybrid Computational Fluid Dynamics and Physiologically Based Inhalation Model for Interspecies Dosimetry Extrapolation of Acidic Vapors in the Upper AirwaysToxicology and Applied Pharmacology, 1998
- Comparison of Inhaled Formaldehyde Dosimetry Predictions with DNA–Protein Cross-Link Measurements in the Rat Nasal PassagesToxicology and Applied Pharmacology, 1997
- Diffusion of nonelectrolytes in the canine trachea: effect of tight junctionJournal of Applied Physiology, 1996
- Incorporation of Nasal-Lining Mass-Transfer Resistance into Acfd Model for Prediction of Ozone Dosimetry in the Upper Respiratory TractInhalation Toxicology, 1996
- Nasal cavity deposition, histopathology, and cell proliferation after single or repeated formaldehyde exposures in B6C3F1 mice and F-344 ratsToxicology and Applied Pharmacology, 1983
- Measurement of tracheal and bronchial mucus velocities in man: relation to lung clearanceJournal of Applied Physiology, 1980
- Algorithms for Minimization Without DerivativesMathematics of Computation, 1974
- The Mechanism of the Oxidation of Acetaldehyde by Chromic AcidBulletin of the Chemical Society of Japan, 1970