New Methods for Microbiological Monitoring at Riverbank Filtration Sites
Open Access
Abstract
Water suppliers aim to achieve microbiological stability throughout their supply system by regular monitoring of water quality. Monitoring temporal biomass dynamics at high frequency is time consuming due to the labor-intensive nature and limitations of conventional, cultivation-based detection methods. The goal of this study was to assess the value of new rapid monitoring methods for quantifying and characterizing dynamic fluctuations in bacterial biomass. Using flow cytometry and two precise enzymatic detection methods, bacterial biomass-related parameters were monitored at three riverbank filtration sites. Additionally, the treatment capacity of an ultrafiltration pilot plant was researched using online flow-cytometry. The results provide insights into microbiological quality of treated water and emphasize the value of rapid, easy and sensitive alternatives to traditional bacterial monitoring techniques.Keywords
Funding Information
- Horizon 2020 Framework Programme (689450)
This publication has 33 references indexed in Scilit:
- Flow cytometry and adenosine tri-phosphate analysis: Alternative possibilities to evaluate major bacteriological changes in drinking water treatment and distribution systemsWater Research, 2012
- Diurnal fluctuations of electrical conductivity in a pre-alpine river: Effects of photosynthesis and groundwater exchangeJournal of Hydrology, 2012
- Composition and stability of bacterial communities associated with granular activated carbon and anthracite filters in a pilot scale municipal drinking water treatment facilityJournal of Water and Health, 2012
- Kinetics of membrane damage to high (HNA) and low (LNA) nucleic acid bacterial clusters in drinking water by ozone, chlorine, chlorine dioxide, monochloramine, ferrate(VI), and permanganateWater Research, 2011
- Fluctuations of electrical conductivity as a natural tracer for bank filtration in a losing streamAdvances in Water Resources, 2010
- Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processesWater Research, 2008
- Quantification of the Filterability of Freshwater Bacteria through 0.45, 0.22, and 0.1 μm Pore Size Filters and Shape-Dependent Enrichment of Filterable Bacterial CommunitiesEnvironmental Science & Technology, 2007
- Heterotrophic plate count bacteria—what is their significance in drinking water?International Journal of Food Microbiology, 2004
- Effect of flood-induced chemical load on filtrate quality at bank filtration sitesJournal of Hydrology, 2002
- Microbiological Safety of Drinking WaterAnnual Review of Microbiology, 2000