Inaccuracy of buccal bone thickness estimation on cone‐beam CT due to implant blooming: An ex‐vivo study
- 25 August 2019
- journal article
- research article
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 46 (11) , 1134-1143
Abstract
Aim: The aim of this article was to evaluate the accuracy of buccal bone thickness measurements around implants on CBCT.Material and methods: Forty‐four Osseospeed EV implants (3.6 in Ø) were placed guided and flapless in five fresh frozen human cadaver heads. The buccal peri‐implant bone was measured clinically via guided bone sounding. Post‐op CBCTs were taken with two different CBCT scanners (NewTom® and Accuitomo®) on which the buccal bone was measured. Consequently, after implant removal, a new CBCT was made without implant artefacts (image reference standard) on which the real buccal bone thickness was scored.Results: Due to an average blooming (artificial increase of implant diameter) percentage of 12%–15%, the buccal peri‐implant bone thickness was underestimated by 0.3 mm on both CBCT devices. Immediately adjacent to the implant blooming area, a doubtful zone of about 0.45 mm was observed in which the buccal bone was not always visible. Buccal bone that was thick enough to fall outside this doubtful zone could always be visualized.Conclusion: The findings in this study may help the clinician in the decision‐making process whether or not to intervene surgically in areas with ambiguous CBCT results.Keywords
This publication has 28 references indexed in Scilit:
- Peri‐implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri‐Implant Diseases and ConditionsJournal of Clinical Periodontology, 2018
- Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomographyJournal of Periodontal & Implant Science, 2018
- Quantitative evaluation of metal artifacts using different CBCT devices, high‐density materials and field of viewsClinical Oral Implants Research, 2017
- Evaluation of peri‐implant buccal bone by computed tomography: an experimental studyClinical Oral Implants Research, 2015
- The impact of implant treatment on oral health related quality of life in a private dental practice: a prospective cohort studyHealth and Quality of Life Outcomes, 2013
- Ultrasound imagery for dental implant diagnosis and treatment planning in a porcine modelThe Journal of Prosthetic Dentistry, 2012
- Sonography of periimplant buccal bone defects in periodontitis patients: A pilot studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2008
- Probe penetration in periodontal and peri‐implant tissues: An experimental study in the beagle dogClinical Oral Implants Research, 2006
- Digital image processing. II. In vitro quantitative evaluation of soft and hard peri‐implant tissue changes.Clinical Oral Implants Research, 1994
- Probing depth at implants and teethJournal of Clinical Periodontology, 1993