Additively manufactured maxillofacial implants and guides – achieving routine use
- 18 January 2016
- journal article
- research article
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 22 (1) , 189-199
Abstract
Purpose: – The purpose of this paper is to identify the key design process factors acting as drivers or barriers to routine health service adoption of additively manufactured (AM) patient-specific devices. The technical efficacy of, and clinical benefits from, using computer-aided design (CAD) and AM in the production of such devices (implants and guides) has been established. Despite this, they are still not commonplace. With AM equipment and CAD tool costs largely outside of the clinician’s or designer’s control, the opportunity exists to explore design process improvement routes to facilitate routine health service implementation.Design/methodology/approach: – A literature review, new data from three separate clinical case studies and experience from an institute working on collaborative research and commercial application of CAD/AM in the maxillofacial specialty, were analysed to extract a list and formulate models of design process factors.Findings: – A semi-digital design and fabrication process is currently the lowest cost and shortest duration for cranioplasty implant production. The key design process factor to address is the fidelity of the device design specification.Research limitations/implications: – Further research into the relative values of, and best methods to address the key factors is required; to work towards the development of new design tools. A wider range of benchmarked case studies is required to assess costs and timings beyond one implant type.Originality/value: – Design process factors are identified (building on previous work largely restricted to technical and clinical efficacy). Additionally, three implant design and fabrication workflows are directly compared for costs and time. Unusually, a design process failure is detailed. A new model is proposed – describing design process factor relationships and the desired impact of future design tools.Keywords
This publication has 37 references indexed in Scilit:
- A design for the additive manufacture of functionally graded porous structures with tailored mechanical properties for biomedical applicationsJournal of Manufacturing Processes, 2011
- Three-dimensional surgical simulationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2010
- Rapid manufacture of custom‐fitting surgical guidesRapid Prototyping Journal, 2009
- Rapid prototyping assisted surgery planning and custom implant designRapid Prototyping Journal, 2009
- A classification of cranial implants based on the degree of difficulty in computer design and manufactureThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Verification of clinical precision after computer-aided reconstruction in craniomaxillofacial surgeryOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Using RP to promote collaborative design of customised medical implantsRapid Prototyping Journal, 2007
- The development of a collaborative medical modelling service: organisational and technical considerationsBritish Journal of Oral and Maxillofacial Surgery, 2004
- Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up studyInternational Journal of Oral and Maxillofacial Surgery, 2003
- The display of three-dimensional anatomy with stereolithographic modelsJournal of Digital Imaging, 1990